Antimonene-Coated Uniform-Waist Tapered Fiber Optic Surface Plasmon Resonance Biosensor for the Detection of Cancerous Cells: Design and Optimization.

ACS Omega

Department of Mechanical Engineering, Politecnico di Milano, Milan20156, Italy.

Published: February 2023

For early-stage cancer detection, a novel design of graphene-antimonene-coated uniform-waist tapered fiber optic surface plasmon resonance (SPR) biosensor is demonstrated. The proposed optical biosensor outperforms over a wide range of refractive index (RI) variations including biological solutions and is designed to detect various cancerous cells in the human body whose RIs are in the range of 1.36-1.4. Here, antimonene is used to enhance the performance of the designed SPR sensor for sensing cancer analytes because of its high binding energy toward adsorption of biomolecules and large active surface area. The design and analysis of the sensor are done with the help of a transfer matrix method-based simulation platform, and the effect of the taper ratio is also studied. The performance of the proposed SPR biosensor is evaluated with performance parameters such as sensitivity, full width at half maximum, detection accuracy (DA), figure of merit (FOM), and limit of detection (LOD). The numerical results show that the designed sensor is able to provide a sensitivity of 7.3465, 10.9250, 11.8914, and 15.2414 μm/RIU, respectively, for sensing skin, cervical, blood, and adrenal gland cancer with a maximum FOM of 131.1525 RIU, DA of 14.2126 μm, and LOD of 7.2 × 10 RIU. Based on the derived results, the authors believe that the designed SPR sensor could practically find its potential applications in the field of medical science for the early-stage diagnosis of cancer and hence, opens a new window in the field of biosensing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909785PMC
http://dx.doi.org/10.1021/acsomega.2c06037DOI Listing

Publication Analysis

Top Keywords

uniform-waist tapered
8
tapered fiber
8
fiber optic
8
optic surface
8
surface plasmon
8
plasmon resonance
8
cancerous cells
8
spr biosensor
8
designed spr
8
spr sensor
8

Similar Publications

Salinity is a very important parameter from an environmental perspective, and therefore, efficient and accurate systems are required for marine environmental monitoring and productive industries. A plasmonic sensor based on doubly deposited tapered optical fibers (DLUWTs-double-layer uniform-waist tapers) for the measurement of salinity is presented. The physical principle of the sensor, as well as its structure, is discussed, and its performance is experimentally demonstrated, obtaining very good sensitivities.

View Article and Find Full Text PDF

Deposition of Graphene Oxide on an SPR Fiber Refractometer for Sensor Applications.

Sensors (Basel)

April 2023

Optics Department, Faculty of Optics and Optometry, University Complutense of Madrid, Arcos de Jalón 118, 28037 Madrid, Spain.

Graphene-based materials have been increasingly incorporated to optical fiber plasmonic sensors due to the peculiar physical and chemical properties of these materials (hardness and flexibility, high electrical and thermal conductivity, and very good adsorption for many substances, etc.). In this paper, we theoretically and experimentally showed how the addition of graphene oxide (GO) to optical fiber refractometers permits the development of surface plasmon resonance (SPR) sensors with very good characteristics.

View Article and Find Full Text PDF

For early-stage cancer detection, a novel design of graphene-antimonene-coated uniform-waist tapered fiber optic surface plasmon resonance (SPR) biosensor is demonstrated. The proposed optical biosensor outperforms over a wide range of refractive index (RI) variations including biological solutions and is designed to detect various cancerous cells in the human body whose RIs are in the range of 1.36-1.

View Article and Find Full Text PDF

Absorption as a selective mechanism in surface plasmon resonance fiber optic sensors.

Opt Lett

November 2006

Departamento de Electrónica, Universidad de Alcalá, Escuela Politecnica, 28871 Alcalá de Henares, Madrid (Spain).

A new concept of surface plasmon resonance fiber optic sensor is presented. By tuning the plasmon resonance to a wavelength for which the outer medium is absorptive, a significant variation of the spectral transmittance of the device is produced as a function of the concentration of the analyte. With this mechanism, selectivity can be achieved without the need of any functionalization of the surfaces or the use of recognizing elements, which is a very interesting feature for any kind of chemical sensor or biosensor.

View Article and Find Full Text PDF

Surface plasmon resonance sensors based on uniform-waist tapered fibers in a reflective configuration.

Appl Opt

October 2006

Departmento de Electrónica, Universidad de Alcalá, Escuela Politécnica, Alcalá de Henares, Madrid, Spain.

We present a configuration for surface plasmon resonance sensors based on uniform-waist tapered optical fibers and reflective elements. Once the fiber is tapered fulfilling the adiabatic criterion, a multilayer including a metallic medium is asymmetrically deposited on the uniform waist of the fiber. This feature provides the resonant excitation of multiple surface plasma waves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!