AI Article Synopsis

  • Inhalation of nanoparticles from toner-based printing equipment is linked to serious health issues like inflammation, cardiovascular disease, and respiratory disorders, especially in TPE operators.
  • A global serum metabolomics study identified 52 biomolecules in these operators, indicating inflammation and immune response changes.
  • A follow-up investigation revealed specific urinary and plasma biomarkers related to DNA damage and oxidative stress metrics elevated in TPE operators, particularly in those with higher exposure levels compared to healthy controls.

Article Abstract

Inhalation of nanoparticles emitted from toner-based printing equipment (TPE), such as laser printers and photocopiers, also known as PEPs, has been associated with systemic inflammation, hypertension, cardiovascular disease, respiratory disorders, and genotoxicity. Global serum metabolomics analysis in 19 healthy TPE operators found 52 dysregulated biomolecules involved in upregulation of inflammation, immune, and antioxidant responses and downregulation of cellular energetics and cell proliferation. Here, we build on the metabolomics study by investigating the association of a panel of nine urinary OS biomarkers reflecting DNA/RNA damage (8OHdG, 8OHG, and 5OHMeU), protein/amino acid oxidation (o-tyrosine, 3-chlorotyrosine, and 3-nitrotyrosine), and lipid oxidation (8-isoprostane, 4-hydroxy nonenal, and malondialdehyde [MDA]), as well as plasma total MDA and total protein carbonyl (TPC), with several nanoparticle exposure metrics in the same 19 healthy TPE operators. Plasma total MDA, urinary 5OHMeU, 3-chlorotyrosine, and 3-nitrotyrosine were positively, whereas o-tyrosine inversely and statistically significantly associated with PEPs exposure in multivariate models, after adjusting for age and urinary creatinine. Urinary 8OHdG, 8OHG, 5OHMeU, and total MDA in urine and plasma had group mean values higher than expected in healthy controls without PEPs exposure and comparable to those of workers experiencing low to moderate levels of oxidative stress (OS). The highest exposure group had OS biomarker values, most notably 8OHdG, 8OHG, and total MDA, that compared to workers exposed to welding fumes and titanium dioxide. Particle number concentration was the most sensitive and robust exposure metric. A combination of nanoparticle number concentration and OS potential of fresh aerosols is recommended for larger scale future studies.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17435390.2023.2175735DOI Listing

Publication Analysis

Top Keywords

total mda
16
8ohdg 8ohg
12
oxidative stress
8
urine plasma
8
healthy tpe
8
tpe operators
8
8ohg 5ohmeu
8
3-chlorotyrosine 3-nitrotyrosine
8
plasma total
8
peps exposure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!