Nyquist Plot Parametrization for Quantitative Analysis of Vibration of the Vocal Folds.

J Voice

University Hospital Erlangen, Medical School Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head & Neck Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany.

Published: February 2023

Objectives: The Nyquist plot provides a graphical representation of the glottal cycles as elliptical trajectories in a 2D plane. This study proposes a methodology to parameterize the Nyquist plot with application to support the quantitative analysis of voice disorders.

Methods: We considered high-speed videoendoscopy recordings of 33 functional dysphonia (FD) patients and 33 normophonic controls (NC). Quantitative analysis was performed by computing four shape-based parameters from the Nyquist plot: Variability, Size (Perimeter and Area), and Consistency. Additionally, we performed automatic classification using a linear support vector machine and feature importance analysis by combining the proposed features with state-of-the-art glottal area waveform (GAW) parameters.

Results: We found that the inter-cycle variability was significantly higher in FD patients compared to NC. We achieved a classification accuracy of 83% when the top 30 most important features were used. Furthermore, the proposed Nyquist plot features were ranked in the top 12 most important features.

Conclusions: The Nyquist plot provides complementary information for subjective and objective assessment of voice disorders. On the one hand, with visual inspection it is possible to observe intra- and inter-glottal cycle irregularities during sustained phonation. On the other hand, shaped-based parameters allow quantifying such irregularities and provide complementary information to state-of-the-art GAW parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvoice.2023.01.014DOI Listing

Publication Analysis

Top Keywords

nyquist plot
24
quantitative analysis
12
nyquist
6
plot
5
plot parametrization
4
parametrization quantitative
4
analysis
4
analysis vibration
4
vibration vocal
4
vocal folds
4

Similar Publications

Article Synopsis
  • BiVO is a stable photocatalytic material but struggles with photocatalytic activity under visible light; this study explores using surfactants to improve its efficiency for degrading tetracycline (TC).
  • The research shows that surfactant-modified BiVO, especially BiVO-CTAC with a specific morphology, enhances light absorption and reduces the energy band gap compared to unmodified BiVO.
  • The findings indicate that the surfactants influence the formation and structure of BiVO, leading to better charge separation and increased degradation efficiency of TC, highlighting a new method for synthesizing effective photocatalysts.
View Article and Find Full Text PDF

A drift-diffusion model is used to investigate the effect of device degradation on current-voltage and impedance measurements of perovskite solar cells (PSCs). Modifications are made to the open-source drift-diffusion software IonMonger to model degradation via an increasing recombination rate during the course of characterization experiments. Impedance spectroscopy is shown to be a significantly more sensitive measure of degradation than current-voltage curves, reliably detecting a power conversion efficiency drop of as little as 0.

View Article and Find Full Text PDF

Hydrogen and renewable fuels were generated using cost-effective and efficient electrocatalysts for water splitting. In this work, a CuO-based photocathode is used for the water splitting to generate hydrogen energy by PVD technique. The XRD analysis reveals the deposition of CuO thin film on ITO substrates, which is monoclinic.

View Article and Find Full Text PDF

We report for the first time the successful acquisition of electrochemical impedance spectroscopy data using an unconventional same-metal PCB-based three-electrode system. Conventional three-electrode systems primarily require expensive and bulky electrodes, and a high volume of analytes to conduct electrochemical impedance spectroscopy studies. The miniaturized PCB-based three-electrode system used in this work requires only trace amounts of analytes in the order of 10-20 μL owing to the design of the electrode sensor.

View Article and Find Full Text PDF

This study presents a biosensor utilizing electrospun SnO nanofiber films for real-time monitoring of C2C12 cells. The biosensor demonstrates sensitivity towards cellular behaviours, including adhesion, proliferation, and detachment. Alterations in semi-circle and dielectric properties are validated through Nyquist plot and an EEC model, highlighting the biosensor's potential for analyzing cellular dynamics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!