AI Article Synopsis

  • Implant migration is an important factor for predicting the longevity of hip joint replacements, and monitoring new hip prostheses is essential during clinical trials.
  • The study developed a CT-based spatial analysis method to measure the migration of ceramic hip implants, which could be a less specialized alternative to the standard RSA method.
  • Results showed that the CT-based method demonstrated comparable accuracy and precision with low radiation exposure, suggesting it could effectively track the movement of hip implants in clinical settings.

Article Abstract

Implant migration is a predictor of arthroplasty survivorship. It is crucial to monitor the migration of novel hip prostheses within premarket clinical investigations. RSA is the gold standard method, but requires calibrated radiographs using specialised equipment. A commercial computed tomography micromotion analysis solution is a promising alternative but is not yet available for use with monobloc ceramic implants. This study aimed to develop and validate a CT-based spatial analysis (CTSA) method for use with ceramic implants. A phantom study was undertaken to assess accuracy and precision. A ceramic hip resurfacing arthroplasty (HRA) and 20 tantalum beads were implanted into a synthetic hip model and mounted onto a 6-degree of freedom motion stage. The hip was repeatedly scanned with a low dose CT protocol, with imposed micromovements. Data were interrogated using a semiautomated technique. The effective radiation dose for each scan was estimated to be 0.25 mSv. For the head implant, precision ranged between 0.11 and 0.28 mm for translations and 0.34°-0.42° for rotations. For the cup implant, precision ranged between 0.08 and 0.11 mm and 0.19° and 0.42°. For the head, accuracy ranged between 0.04 and 0.18 mm for translations and 0.28°-0.46° for rotations. For the cup, accuracy ranged between 0.04 and 0.08 mm and 0.17° and 0.43°. This in vitro study demonstrates that low dose CTSA of a ceramic HRA is similar in accuracy to RSA. CT is ubiquitous, and this method may be an alternative to RSA to measure prosthesis migration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10052406PMC
http://dx.doi.org/10.1177/09544119231153905DOI Listing

Publication Analysis

Top Keywords

low dose
12
ct-based spatial
8
spatial analysis
8
analysis ctsa
8
implant migration
8
ceramic hip
8
hip resurfacing
8
resurfacing arthroplasty
8
arthroplasty hra
8
phantom study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!