Accurate and reproducible color capture is vital in medical photography. Camera distance and angle are particularly important as they are highly variable in a clinical setting. To account for variability in illumination, camera technology, and geometric effects, color standards are often used for color correction. To explore how geometry affects color, we quantified the change in CIELAB color value of a color standard for diverse skin tones at varying smartphone camera distances and angles. Whereas both chromaticity (a* and b*) and lightness (L*) were affected by angle, distance only affected L* (standard error of measurement, SEM > 1 CIELAB unit). Flash usage did not generally reduce distance and angle associated variability. Compared to compressed (JPG) format, raw (DNG) images had decreased median variability across different distances and angles. These findings suggest that in medical photography, inconsistent camera distance and angle can increase variability in photographed skin appearance over time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10247498 | PMC |
http://dx.doi.org/10.1002/jbio.202200381 | DOI Listing |
J Plast Surg Hand Surg
January 2025
Department of Clinical Sciences in Malmö, Lund University, Lund, Sweden; Department of Oral and Maxillofacial Surgery, Skåne University Hospital, Malmö, Sweden; Department of Orthodontics, Malmö University, Malmö, Sweden.
Pre- and postoperative photos to assess results are widely used in plastic and reconstructive surgery, for instance, in patients with cleft lip and palate (CL/P). Evaluations are often performed by assessment panels by viewing the photos. However, these are prone to be subjective.
View Article and Find Full Text PDFLangmuir
January 2025
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China.
Cavitation has been a hot research topic for scholars in various fields because of the intense mechanical, chemical, and thermal effects of bubble collapse. It forms a cluster of bubbles, and the bubbles will affect, interfere with, and couple with each other. To grasp the main factors affecting bubble collapse and the interbubble mechanism, the paper adopts the molecular dynamics simulation combined with the coarse-grained force field to study the collapse process of the double bubble model and takes the dynamic shape change of the bubbles, the local velocity distribution, and the local pressure distribution as the object to summarize the position angle, the shock velocity, and the bubble distance on the collapse law and the primary and secondary influence relationship and then reveals the interbubble mechanism.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Engineering Physics, Tsinghua University, Beijing, China.
Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by object's micro-structures. This technique is sensitive to the porous microstructure of lung alveoli and has the potential to detect lung diseases at an early stage. Up to now, a human-scale dark-field CT (DF-CT) prototype has been built for lung imaging.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Qau, Islamabad, Islamabad, 44000, PAKISTAN.
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
Purpose: Descemet membrane endothelial keratoplasty (DMEK) has emerged as a novel approach in corneal transplantation over the past two decades. This study aims to identify predisposing risk factors for post-DMEK ocular hypertension (OHT) and develop a preoperative predictive model for post-DMEK OHT.
Methods: Patients who underwent DMEK at Gangnam Severance Hospital between 2017 and 2024 were included in the study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!