This paper describes an affordable robotic mobile 3D mapping system. It is built with Livox Mid-40 lidar with a conic field of view extended by a custom rotating planar reflector. This 3D sensor is compared with the more expensive Velodyne VLP 16 lidar. It is shown that the proposed sensor reaches satisfactory accuracy and range. Furthermore, it is able to preserve the metric accuracy and non-repetitive scanning pattern of the unmodified sensor. Due to preserving the non-repetitive scan pattern, our system is capable of covering the entire field of view of 38.4 × 360 degrees, which is an added value of conducted research. We show the calibration method, mechanical design, and synchronization details that are necessary to replicate our system. This work extends the applicability of solid-state lidars since the field of view can be reshaped with minimal loss of measurement properties. The solution was part of a system that was evaluated during the 3rd European Robotics Hackathon in the Zwentendorf Nuclear Power Plant. The experimental part of the paper demonstrates that our affordable robotic mobile 3D mapping system is capable of providing 3D maps of a nuclear facility that are comparable to the more expensive solution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920869PMC
http://dx.doi.org/10.3390/s23031551DOI Listing

Publication Analysis

Top Keywords

affordable robotic
12
robotic mobile
12
mobile mapping
12
mapping system
12
field view
12
rotating planar
8
planar reflector
8
system capable
8
system
6
system based
4

Similar Publications

Light-Programmable g-CN Microrobots with Negative Photogravitaxis for Photocatalytic Antibiotic Degradation.

Research (Wash D C)

January 2025

Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Brno 61200, Czech Republic.

Microrobots enhance contact with pollutants through their movement and flow-induced mixing, substantially improving wastewater treatment efficiency beyond traditional diffusion-limited methods. g-CN is an affordable and environmentally friendly photocatalyst that has been extensively researched in various fields such as biomedicine and environmental remediation. However, compared to other photocatalytic materials like TiO and ZnO, which are widely used in the fabrication of micro- and nanorobots, research on g-CN for these applications is still in its early stages.

View Article and Find Full Text PDF

Background: This paper describes the rationale and design of the RECOVER study. Currently, there is no consensus regarding the optimal treatment for high-risk, non-metastatic prostate cancer (PCa). The study primarily aims to evaluate and compare the impact of treatment with robot-assisted radical prostatectomy (RP) versus external beam radiation therapy (EBRT) with androgen deprivation therapy (ADT) for men with high-risk, non-metastatic PCa regarding health-related quality of life (HRQoL) and functional outcomes.

View Article and Find Full Text PDF

Ultrasound imaging is widely valued for its safety, non-invasiveness, and real-time capabilities but is often limited by operator variability, affecting image quality and reproducibility. Robot-assisted ultrasound may provide a solution by delivering more consistent, precise, and faster scans, potentially reducing human error and healthcare costs. Effective force control is crucial in robotic ultrasound scanning to ensure consistent image quality and patient safety.

View Article and Find Full Text PDF

The application of artificial intelligence (AI) to healthcare in Africa has the potential to transform productivity, diagnosis, disease surveillance, and resource allocation by improving accuracy and efficiency. However, to fully realize its benefits, it is necessary to consider issues concerning data privacy, equity, infrastructure integration, and ethical policy development. The use of these tools may improve the detection of diseases, the distribution of resources, and the continuity of care.

View Article and Find Full Text PDF

Cost-effectiveness of robotic mastectomy vs. conventional mastectomy: A long-term economic evaluation from a Singapore healthcare perspective.

Eur J Surg Oncol

January 2025

Division of Breast Surgery, Department of Surgery, Changi General Hospital, Singapore; SingHealth Duke-NUS Breast Centre, Singapore. Electronic address:

Importance: Breast cancer is the most prevalent cancer among women globally, and Singapore is no exception. Surgical intervention, especially mastectomy, is a cornerstone of breast cancer treatment. While conventional mastectomy (CM) has been the gold standard, robotic mastectomy (RM) has emerged as a promising alternative due to its minimally invasive nature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!