The paper presents the validation of an electrochemical procedure for on-site Hg ions determination in wastewater samples using a modified carbon screen-printed electrode (SPE) with a complexing polymeric film based on poly(2,2'-(ethane-1,2-diylbis((2-(azulen-2-ylamino)-2-oxoethyl)azanediyl))diacetic acid) (poly). Using metal ions accumulation in an open circuit followed by anodic stripping voltammetry, the SPE-poly electrode presents a linear range in the range of 20 µg/L to 150 µg/L, with a limit of detection (LOD) = 6 µg/L, limit of quantification (LOQ) = 20 µg/L, and an average measurement uncertainty of 26% of mercury ions. The results obtained in situ and in the laboratory using the SPE-poly modified electrode were compared with those obtained by the atomic absorption spectrometry coupled with the cold vapor generation standardized method, with the average values indicating excellent recovery yields.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919054 | PMC |
http://dx.doi.org/10.3390/s23031084 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!