Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study investigated the shear resistance and damage evolution of glass fiber-reinforced polymer (GFRP)-reinforced concrete short columns. Five circular concrete short columns reinforced with GFRP bars and spiral stirrups were fabricated and tested under lateral thrust in the laboratory. The test variables involved the stirrup reinforcement ratio, the longitudinal reinforcement ratio and the type of stirrups. The failure modes, load-displacement curves, strain responses and crack characteristics of these columns were documented and discussed. The accuracy of shear design equations in predicting shear capacity of such columns was evaluated. In addition, the digital image correlation (DIC) instrument was used to identify the full-field strain and damage zones of circular concrete short columns. Several smart aggregate (SA) transducers coupled to the surface of these columns were used to monitor its damage status. The energy ratio index (ERI) and the damage index based on smart aggregate were established to characterize damage level of such columns. The test results indicate that the shear capacity is improved 5.6% and 31.1% and the lateral ultimate displacement is increased 67.7% and 400% as the stirrup reinforcement ratio of the concrete short column is increased from 0 to 0.19% and 0.47%, respectively. The shear capacity equation proposed by Ali and his co-workers, considering a strain limit of 0.004Efv, gives accurate predictions of the shear capacity of circular concrete short columns reinforced with GFRP bars and spiral stirrups. The variation in ERI values is explained by the development of damage zones of the column obtained with DIC technology and with the proposed damage index based on the smart aggregate it is feasible to evaluate the damage level of circular short concrete columns.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919007 | PMC |
http://dx.doi.org/10.3390/polym15030567 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!