Adding organically modified bentonite into impervious wall materials may improve the adsorption of organic pollutants. In this study, cetyltrimethylammonium bromide organically modified bentonite (CTMAB bentonite) was mixed with sodium bentonite and kaolin to obtain two materials, which were then used as cut-off walls for typical pollutants. Soil column consolidation tests, diffusion tests, and breakdown tests were conducted to study migration of organic pollutants in soil columns. The parameter sensitivity of pollutant transport in the cut-off wall was analysed by numerical simulation. The sodium bentonite mixed with 10% CTMAB bentonite and kaolin-CTMAB bentonite showed the greatest impermeability: with a consolidation pressure of 200 kPa, the permeability coefficients were 1.03 × 10 m/s and 3.49 × 10 m/s, respectively. The quantity of phenol adsorbed on sodium bentonite-CTMAB bentonite increased with increasing water head height. The kaolin-CTMAB bentonite column showed the best rhodamine B adsorption performance, and the adsorption rate reached 98.9% on day 67. The numerical results showed that the permeability coefficient was positively correlated with the diffusion of pollutants in the soil column. The quantity adsorbed on the soil column was positively correlated with the retardation factor, and the extent of pollutant diffusion was negatively correlated with the retardation factor. This study provides a technical means for the optimal design of organic pollutant cut-off walls.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9918996 | PMC |
http://dx.doi.org/10.3390/ma16031255 | DOI Listing |
Diagn Interv Imaging
November 2024
Department of Radiology, University of Franche-Comté, CHRU Besançon, 25000 Besançon, France; EA 4662 Nanomedicine Lab, Imagery and Therapeutics, University of Franche-Comté, 25000 Besançon, France. Electronic address:
Purpose: The purpose of this study was to determine whether dual-energy computed tomography (DECT), specifically by measuring bowel wall iodine concentration (BWIC), is superior to monoenergetic reconstructions (MR) for the diagnosis and staging of small bowel ischemia in patients with mechanical small bowel obstruction (SBO).
Materials And Methods: From November 2021 to December 2023, all patients with mechanical SBO who underwent contrast-enhanced DECT of the abdomen and pelvis were evaluated for inclusion. Demographic, clinical and biochemical data were collected.
Cardiol Young
November 2024
Department of Pediatric Cardiology, Masonic Children's Hospital, University of Minnesota, Minneapolis, MN, USA.
Soft Matter
November 2024
Department of Chemistry, Technische Universität Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany.
A confined bicontinuous CE-DO--octane microemulsion is studied using neutron spin echo spectroscopy (NSE). Controlled pore glasses serve as confining matrices with pore diameters ranging from 24 to 112 nm. Firstly, the microemulsion in bulk is investigated by NSE and dynamic light scattering, which allows the determination of the unperturbed collective dynamics as well as the observation of the undulation of the surfactant film.
View Article and Find Full Text PDFWater Res
December 2024
MOE Key Laboratory of Soft Soils and Geoenvironmental Engineering, Zhejiang University, Hangzhou, 310058, PR China.
An analytical model was developed to assess the service time of the barrier system consisting of a two-layer cover system and a cut-off wall. The recursive method is used to evaluate the influence of the variable head loss boundary condition caused by the water infiltration. The impact of the types of cover systems and cut-off walls on the barrier system performance is assessed.
View Article and Find Full Text PDFPacing Clin Electrophysiol
November 2024
Department of Cardiology, Electrophysiology and Rhythmology, Krankenhaus Porz am Rhein, Cologne, Germany.
Background: Low voltage areas (LVA) are pivotal in atrial fibrillation (AF) pathogenesis, influencing local left atrial LA excitation and perpetuating AF occurrences. While pulmonary vein isolation (PVI) with cryo-balloon (CB) ablation is effective for AF, it doesn't provide insights into the LA substrate or detect LVA, which affects ablation success rates. This study examines whether LA voltage and LVAs can be anticipated by analyzing the voltage signal amplitude at the coronary sinus (CS) catheter, which is standard in CB and radiofrequency ablation procedures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!