Background: The inaccurate maxillomandibular relationship of virtual casts following alignment by the vestibular scan may result in intersection (intermesh penetration) between opposing dental arch surfaces. Intersection occurs at short interocclusal distances in the occlusal contact area (OCA) and may result in infra-occluded definitive restorations. The purpose of this clinical study was to compare initial (by the proprietary scanner software) and new alignments (by a standalone 3D software) of virtual casts regarding OCA and intersection failure. New alignments aimed to rectify intersections by refinement of occlusal contacts.

Material And Methods: The virtual casts of 30 patients following digital and conventional impression-taking were analyzed, which were acquired for single implant restoration in the posterior site. Digital impressions were performed by both IOS 1 (3M True Definition) and IOS 2 (TRIOS 3), either as complete- or partial-arch scans, respectively. Mounted gypsum casts were digitized as complete-arch by a laboratory scanner (LS) in enabled and disabled mode to avoid intersection [LS (+)/LS (-)]. All virtual casts were newly aligned by a 3D software. The difference of the OCA and the area of intersection were calculated for initial and new alignments, using interocclusal distance ranges of 0-100 μm, 0-10 μm or <0 μm (=intersection). The difference of the OCA was compared using a linear mixed model. The distribution of occlusal contact points per modality and alignment was assessed independently by three observers and estimated by inter- and intraclass correlation (ICC) coefficients.

Results: Virtual casts following initial alignment demonstrated intersections irrespective of the modality. The mean area of the intersection was most for IOS 2 (79.23 mm), followed by IOS 1 (48.28 mm), LS (-) (2.77 mm), and LS (+) (2.01 mm) in partial-arch scans. Complete-arch scans demonstrated an area of intersection of 70.63 mm for IOS 1 followed by 65.52 mm (IOS 2), 6.13 mm [LS (-)] and 2.76 mm [LS (+)]. Newly aligned scans showed no intersections. The overall distribution of occlusal contact points demonstrated moderate reliability (ICC 0.63). Good reliability could be observed (ICC 0.9) for LS (-) scans.

Conclusions: Intersections in the area of occlusal contact points are a phenomenon restricted to virtual casts, which should be considered in CAD/CAM. Initial alignments of LS are less affected by this virtual phenomenon, and contact points may be more distinct according to their anatomic region compared to IOS. Furthermore, intersections can be rectified in a 3D software by adjustment of the maxillomandibular relationship.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9917590PMC
http://dx.doi.org/10.3390/jcm12030996DOI Listing

Publication Analysis

Top Keywords

virtual casts
16
intersection
6
casts
5
comparison virtual
4
virtual intersection
4
intersection occlusal
4
occlusal contacts
4
contacts intraoral
4
intraoral laboratory
4
laboratory scans
4

Similar Publications

Ultrasmall micro-light-emitting diodes (μLEDs), sized below 10 μm, are indispensable to create the next-generation augmented and virtual reality (AR/VR) devices. Their high brightness and low power consumption could not only enhance the user experience by providing vivid and lifelike visuals but also extend device longevity. However, a notable challenge emerges: a decrease in efficiency with a reduced size.

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy of intraoral scanners (IOSs) for fabricating inlay, onlay, and veneer restorations.

Materials And Methods: A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, Web of Science, and Cochrane. A manual search was also conducted.

View Article and Find Full Text PDF

Since laparoscopic surgery became the gold standard for colorectal procedures, specific skills are required to achieve good outcomes. The best way to acquire basic and advanced skills and reach the learning curve plateau is by using dedicated simulators: box-trainers, video-trainers and virtual reality simulators. Laparoscopic skills training outside the operating room is cost-beneficial, faster and safer, and does not harm the patient.

View Article and Find Full Text PDF

Nocebo effects in pain (nocebo hyperalgesia) have received significant attention recently, with negative expectancies and anxiety proposed to be explanatory factors. While both expectancy and anxiety can bias attention, attention has been rarely explored as a potential mechanism involved in nocebo hyperalgesia. The present study aimed to explore whether attention bias modification (ABM) using an immersive, ecologically valid VR paradigm successfully induced attention biases (AB) and subsequently influenced nocebo hyperalgesia.

View Article and Find Full Text PDF

Computer-assisted preparation of porcelain laminate veneers (PLVs) using stereolithographic templates has been developed to enhance the accuracy of tooth preparation. However, the digital workflows involved in guided PLV preparation remain inconsistently defined across various practices. Therefore, this scoping review aimed to examine publications on computer-assisted PLV preparation to identify the key stage of digital workflows involved in designing and fabricating stereolithographic templates, as well as to highlight the limitations of various template designs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!