This study evaluated the feasibility of reducing the radiation dose in abdominal imaging of urolithiasis with a clinical photon-counting CT (PCCT) by gradually lowering the image quality level (IQL) without compromising the image quality and diagnostic value. Ninety-eight PCCT examinations using either IQL70 (n = 31), IQL60 (n = 31) or IQL50 (n = 36) were retrospectively included. Parameters for the radiation dose and the quantitative image quality were analyzed. Qualitative image quality, presence of urolithiasis and diagnostic confidence were rated. Lowering the IQL from 70 to 50 led to a significant decrease (22.8%) in the size-specific dose estimate (SSDE, IQL70 4.57 ± 0.84 mGy, IQL50 3.53 ± 0.70 mGy, < 0.001). Simultaneously, lowering the IQL led to a minimal deterioration of the quantitative quality, e.g., image noise increased from 9.13 ± 1.99 (IQL70) to 9.91 ± 1.77 (IQL50, = 0.248). Radiologists did not notice major changes in the image quality throughout the IQLs. Detection rates of urolithiasis (91.3-100%) did not differ markedly. Diagnostic confidence was high and not influenced by the IQL. Adjusting the PCCT scan protocol by lowering the IQL can significantly reduce the radiation dose without significant impairment of the image quality. The detection rate and diagnostic confidence are not impaired by using an ultra-low-dose PCCT scan protocol.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914353 | PMC |
http://dx.doi.org/10.3390/diagnostics13030458 | DOI Listing |
Head Neck
January 2025
Department of Endocrinology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Background: Locoregional external beam radiotherapy (EBRT) is selectively used in thyroid cancer patients to induce locoregional control. However, despite technological advances, EBRT remains associated with toxicities. We evaluated thyroid-cancer specific toxicities and long-term Quality of Life (QoL) post-EBRT.
View Article and Find Full Text PDFAm J Nucl Med Mol Imaging
December 2024
Cyclotron and Radiochemistry Core, Karmanos Cancer Institute Detroit, MI, USA.
Colony-stimulating factor 1 receptor (CSF1R) is almost exclusively expressed on microglia in the human brain and thus, has promise as a biomarker for imaging microglia density as a proxy for neuroinflammation. [C]CPPC is a radiotracer with selective affinity to CSF1R, and has been evaluated for in-human microglia PET imaging. The flourine-18 labeled CPPC derivative, 5-cyano-N-(4-(4-(2-[F]fluoroethyl)piperazin-1-yl)-2-(piperidin-1-yl)phenyl)furan-2-carboxamide ([F]FCPPC), was previously synthesized, however, with a low radiochemical yield using manual radiosynthesis.
View Article and Find Full Text PDFTrauma Surg Acute Care Open
December 2024
Department of Surgery, Division of Trauma & Acute Care Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
Background: Bedside thoracic ultrasound (US) offers numerous advantages over chest X-ray (CXR) for identification of recurrent pneumothoraces (PTX) after tube thoracostomy (TT) removal. Technologic advancements have led to the development of hand-held devices capable of producing high-quality images termed ultra-portable US (UPUS). We hypothesized that UPUS would be as successful as CXR in detecting post-TT removal PTX and would be preferred by patients.
View Article and Find Full Text PDFData Brief
February 2025
Department of Computer Science and Engineering, East West University, Aftabnagar, Dhaka, Bangladesh.
In the field of agriculture, particularly within the context of machine learning applications, quality datasets are essential for advancing research and development. To address the challenges of identifying different mango leaf types and recognizing the diverse and unique characteristics of mango varieties in Bangladesh, a comprehensive and publicly accessible dataset titled "BDMANGO" has been created. This dataset includes images essential for research, featuring six mango varieties: Amrapali, Banana, Chaunsa, Fazli, Haribhanga, and Himsagar, which were collected from different locations.
View Article and Find Full Text PDFAberrant anatomical variation of the vertebral artery (VA) from an internal carotid artery (ICA) is considered a rare finding. The incidence of this phenomenon can lead to patients suffering from posterior circulation neurological deficit if the ICA becomes significantly diseased. VA atypical anatomical origin is considered one of the rare pathologies, not only precipitating neurovascular incidents but equally leading to severe difficulty in VA dissection and surgical exposure, especially in carotid artery procedures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!