Aortic arch pathologies are commonly treated by open surgery which is still the gold standard. Patients that are unfit for surgery can be effectively treated mini-invasively with novel endovascular endograft specifically designed for the arch. Endovascular technology has remarkably improved in recent years and is a valid alternative option for the treatment of aortic arch. Available endografts on the market include fenestrated and branched (single, double, or triple). Most endograft designed for the aortic arch are custom-made and production time could be limiting. The aim of this study is to report our experience with the only single branch bi-modular off-the shelf device available on the market specifically designed for aortic arch aneurysms and dissections. We perform endovascular treatment of the arch in a multidisciplinary team together with dedicated anesthesiologist team, interventional cardiologists, and cardiac surgeons. Prior to the implantation of the endograft, a debranching procedure must be made to redirect the blood from brachiocephalic trunk (BCT) to the left common carotid artery and left subclavian artery. A through and through system from the right axillary artery to the femoral artery is required to deploy the main module. The ascending module is delivered over an extra stiff guidewire placed in the left ventricle. Molding of the endografts is performed with kissing balloon in rapid pacing. We performed 8 cases. Six of them came to our attention for residual dissection and has already been treated with ascending aorta replacement. Mean aortic diameter was 63 mm. All patients required complete debranching of the supra-aortic vessel and received a right common carotid -left subclavian artery bypass with reimplantation of the left common carotid artery on the graft. Timing of the debranching was a few days before the endovascular procedure in 76% of cases. Technical success of the endovascular intervention occurred in 100% of cases. In 2 cases the target supra-aortic trunk for the deployment of the main module BCT branch was the left subclavian artery with no adverse event related to this variation. No intraoperative adjunctive maneuvers have been registered, left subclavian artery have been embolized during the procedure in 5 cases. No access complications have been reported. We experienced 1 case of major stroke with permanent neurological impairments that lead to worsening of clinical condition and death at 6 months. No cardiological adverse event have been registered. Two cases of type 2 endoleak have been reported and required reintervention with embolization of the LSA. At 1 year follow-up no aorta-related adverse event has been reported. The use of this off-the-shelf device for the treatment of aortic arch pathologies requiring total debranching of the supra-aortic vessels seems to be safe and effective. Preliminary results are promising despite available data are insufficient and further data collection is mandatory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S0021-9509.22.12577-2 | DOI Listing |
Eur J Cardiothorac Surg
January 2025
Department of Paediatrics, Dr D. Y. Patil Medical College Hospital and Research Centre, Dr D. Y. Patil Vidyapeeth (Deemed-to-be-University), Pimpri, Pune - 411018, Maharashtra, India.
Gen Thorac Cardiovasc Surg
January 2025
Department of Cardiovascular Surgery, Nerima Hikarigaoka Hospital, 1-5-2, Hikarigaoka, Nerima-ku, Tokyo, Japan.
Objective: Branched prostheses are used to treat aortic arch with dissection. However, changes in the neck vessel geometry and diameter after dissection are not well known. We aimed to evaluate neck vessels geometry and changes in diameter with dissection.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany.
: In the presence of porcelain aorta (PA), transcatheter aortic valve replacement (TAVR) has become a class I therapeutic indication for the treatment of severe aortic valve stenosis. To date, few studies have analyzed the clinical outcomes of TAVR in PA patients. We aim to analyze the calcification patterns of the thoracic aorta in PA patients and to evaluate their clinical implications for TAVR procedures.
View Article and Find Full Text PDF: EnBloc resections of bone tumors of the spine are very demanding as the target to achieve a tumor-free margin specimen (sometimes impossible due to the extracompartimental tumor extension) is sometimes conflicting with the integrity of neurological functions and spine stability. : The surgical treatment of a huge multi-level chordoma of the thoracic spine with unusual extension is reported. Anteriorly, the tumor widely invaded the mediastinum and displaced the aorta; on the left side, it expanded in the subpleuric region; posteriorly, it was uncommonly distant 13 mm from the posterior wall.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!