Purpose: To retrospectively assess clinical and radiographic outcomes of immediately loaded full-arch fixed prostheses supported by axial and tilted implants up to 15 years of function.

Materials And Methods: Patients with one completely edentulous arch received an immediate full-arch fixed prosthesis supported by two anterior axial and two posterior tilted implants. Definitive prosthesis consisting of a CAD-CAM titanium framework and acrylic teeth was delivered 6 months later. Patients were regularly followed to assess clinical parameters and marginal bone level (MBL) change. Multilevel regression analysis was performed to investigate factors affecting implant failure and MBL.

Results: Six hundred ninety-two implants were placed in 72 maxillae and 101 mandibles. Seven maxillary implants (5 axial and 2 tilted) in 6 patients and 12 mandibular implants (6 axial and 6 tilted) in 5 patients failed. 15-year cumulative implant survival was 97.51% and 96.91% in maxilla and mandible, respectively (p = .64). After 10 years, the difference in MBL between axial and tilted implants was not significant in the maxilla (p = .47, 65 patients), while it was in the mandible (p < .001, 80 patients). Significant higher bone loss was reported in the mandible at both 5- and 10-year follow-up (p < .001 and p = .004, respectively). Mixed-effect multilevel linear regression evidenced a correlation between arch and bone loss at 5- and 10-year follow-up, while no correlation was found with age, gender, smoking, diabetes, and history of periodontal disease.

Conclusion: This long-term study suggests that the present technique can be considered a viable treatment modality for the immediate rehabilitation of both maxilla and mandible.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.14047DOI Listing

Publication Analysis

Top Keywords

axial tilted
20
tilted implants
16
full-arch fixed
12
fixed prostheses
8
prostheses supported
8
supported axial
8
assess clinical
8
implants axial
8
tilted patients
8
implants
7

Similar Publications

Correlations Between the Pterygomaxillary Junction and Appropriate Osteotome Placement Angles During Junction Separation in Le Fort I Osteotomy.

J Craniofac Surg

December 2024

Department of Plastic and Reconstructive Surgery and Craniofacial Research Center, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan, Taiwan.

Purpose: The authors evaluated pterygomaxillary junction angles across malocclusion patterns and identified the optimal technique for effective pterygomaxillary junction separation during Le Fort I osteotomy, focusing on appropriate osteotome angles and clinical applications.

Methods: This retrospective study included 211 patients with malocclusion who had undergone Le Fort I osteotomy at Chang Gung Craniofacial Center between December 2015 and September 2023. The patients were stratified by sex and malocclusion class (class I, II, or III).

View Article and Find Full Text PDF

Axial elongation in nonpathologic high myopia: Ocular structural changes and glaucoma diagnostic challenges.

Asia Pac J Ophthalmol (Phila)

December 2024

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China. Electronic address:

Axial elongation continues in highly myopic adult eyes, even in the absence of pathologic changes such as posterior staphyloma or chorioretinal atrophy. This ongoing axial elongation leads to structural changes in the macular and peripapillary regions, including chorioretinal thinning, reduced vascular perfusion and optic disc tilting and rotation, among others. These alterations can affect the acquisition and interpretation of optical coherence tomography, optical coherence tomography angiography and fundus photographs, potentially introducing artifacts and diminishing the accuracy of glaucoma diagnosis in highly myopic eyes.

View Article and Find Full Text PDF

Coaxial Helices in Chiral Supramolecular Aggregates from Highly Hindered Chiral Allenes.

Angew Chem Int Ed Engl

December 2024

CINBIO and Departamento de Química Orgánica, Campus Lagoas-Marcosende, Universidade de Vigo, Vigo, E-36310, Spain.

Chiral allenes self-assembly following a cooperative mechanism into a supramolecular chiral aggregate consisting of two coaxial helices: the internal helix described by the allene stack and the external helix which consist in a 4-helix described by the four allene substituents. More precisely, this supramolecular aggregate possesses six axially chiral elements within its structure-the allene, the allene stack (internal helix) and the stacks of the four allene substituents (external 4-helix)-. Interestingly, slight variations in the magnitude of the tilting degree while keeping its P- or M- orientation (internal helix) can vary the orientation of the 4-axial motifs at the external helix.

View Article and Find Full Text PDF

Purpose: This retrospective comparative study aimed to compare the native patellar alignment and clinical outcomes of the Rotating Concave-Convex (ROCC) knee, which features a saddle-shaped rotating platform (RP) insert and a deep trochlea, versus the low contact stress (LCS) knee, which has favourable long-term outcomes and features an anatomically shaped trochlea and a cruciate-sacrificing RP insert. We hypothesized that the deeper trochlea of the ROCC would further stabilize the native patella, resulting in superior clinical outcomes compared to LCS-RP.

Methods: Consecutive patients who underwent patellar-nonresurfacing primary total knee arthroplasty (TKA) using ROCC or LCS-RP were retrospectively reviewed.

View Article and Find Full Text PDF

Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!