Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate rotational stability, decentration and tilt of the monofocal intraocular lens (IOL) Nanex (NC1-SP; HOYA Surgical Optics).
Design: Prospective interventional case series.
Methods: The study was performed at the Department of Ophthalmology, Medical University of Vienna. The study population comprised 130 eyes of 68 patients with age-related cataract who underwent cataract surgery with implantation of a Nanex IOL. Baseline image for rotational stability evaluation was obtained at the end of surgery (EoS) and compared to retroillumination images taken at 1 hour, 1 week, 1 month, and 6 months after surgery. Axis alignment was assessed using nonmovable landmarks on the sclera and the optic-haptic junctions of the IOL. Anterior segment OCT images were performed to evaluate decentration and tilt. The main outcome measure was absolute rotation from EoS to 6 months postoperatively.
Results: Median IOL rotation of all eyes from EoS to 6 months was 1.9° (interquartile range 0.1°-37.5°). Ten eyes (9.71%) rotated more than 5° and 2 eyes (1.94%), more than 10°. IOL rotation did not correlate with axial eye length (Spearman r = -0.042, P = .46), crystalline lens thickness (Spearman r = 0.134, P = .19), and crystalline lens equatorial diameter (Spearman r = 0.101, P = .325). IOL rotation positively correlated with anterior fibrosis severity (Spearman r = 0.321, P = .002). Preoperative decentration (0.2 ± 0.12 mm) and tilt (5.7 ± 1.6°) did not change significantly after surgery (0.22 ± 0.12 mm and 5.62 ± 1.49°, respectively).
Conclusion: The investigated IOL presented good rotational stability and low decentration and tilt values. Nevertheless, anterior capsule fibrosis development led to a higher tendency of IOL rotation after 1 week.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajo.2023.01.026 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!