A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Virtual simulations in planning intravascular treatment of aortic coarctation - a retrospective analysis. | LitMetric

Introduction: A number of studies on using both three-dimensional printing and virtual models in assessment of aortic coarctation have been published, yet none of them uses virtual modelling as a planning tool in a blind retrospective analysis.

Aim: Assessment of virtual modelling and virtual reality in planning interventional treatment of aortic coarctation.

Material And Methods: The study involved computed tomography scans of 20 patients performed prior to interventional treatment of aortic coarctation, which were used to create a virtual three-dimensional model of the aorta in Materialise Mimics. A group of potential stents was modelled in Materialise 3-Matic and complete simulations were assessed in Mimics Viewer using a virtual reality headset in order to choose an optimal stent, which was later compared with the implanted one.

Results: In 5 cases identical or very similar stents were proposed, in 12 cases simulations had slight, potentially avoidable misestimations either in stent length or diameter, and in 3 cases differences were more considerable. Overall, in 14 cases the location of the stent was concordant between the simulation and reality and in the remaining 6 cases the simulated stent was located lower than the actual one.

Conclusions: The method of computer modelling provided a satisfactory success rate of predicting the possible stents to use during the procedure. Differences in chosen stents may have been caused by individual experience in interventional cardiology, the lack of availability of certain stents in the heart catheterization laboratory, the lack of information about the diameter of the vascular access and differences in dimensions measured on the model, tomography and angiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885225PMC
http://dx.doi.org/10.5114/aic.2022.120377DOI Listing

Publication Analysis

Top Keywords

treatment aortic
12
aortic coarctation
12
virtual modelling
8
virtual reality
8
interventional treatment
8
virtual
7
stents
5
cases
5
virtual simulations
4
simulations planning
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!