A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of continuous and slow tracheal tube cuff deflation on cough reflex during extubation in noncardiac surgery patients: a randomised clinical trial. | LitMetric

Effects of continuous and slow tracheal tube cuff deflation on cough reflex during extubation in noncardiac surgery patients: a randomised clinical trial.

BMC Anesthesiol

Department of Anesthesiology, Benq medical center & Jinling Hospital, Jinling School of Clinical Medicine, Nanjing Medical University, No. 71 Hexi Avenue, Jianye District, Jiangsu Province, 210019, Nanjing, People's Republic of China.

Published: February 2023

Background: The incidence of cough reflex during extubation is 76%. Cough reflex causes severe hemodynamic fluctuations and airway complications. This prospective trial investigated the potential effects of tracheal tube cuff deflation on cough reflex during extubation.

Methods: One hundred and twenty-six patients scheduled for operations within 3 h under general anaesthesia with orotracheal intubation were randomly assigned to one of three groups: control (C), experimental (E) or syringe (S) groups. Patients in group C underwent tracheal tube cuff deflation using a 10-ml syringe in 1 s, patients in group E underwent tracheal tube cuff deflation continuously and slowly in 5 s using a cuff pressure gauge until the pressure was zero and patients in group S underwent tracheal tube cuff deflation using a 10-ml syringe at a speed of 1 ml s. The incidence and severity of cough reflexs during extubation and the incidence of postoperative airway complications within 48 h were assessed.

Results: Compared with group C (60.0%), the incidence of cough reflex in group E was 9.8% (p < 0.001) and in group S was 12.5% (p < 0.001). The severity of cough reflex was graded as 2 (1-2) in group C, 1 (1-1) in group E and 1 (1-1) in group S (p < 0.001 for group comparisons). The incidence of hoarseness in group C was 0.0%, in group E was 19.5% and in group S was 5.0% (p < 0.05 for all groups, p = 0.009 between group C and E).

Conclusions: Compared with deflating a trachal tube cuff with a 10-ml syringe in 1 s, the use of a 10-ml syringe at a speed of 1 ml s or a cuff pressure guage within 5 s can both reduce the incidence of cough reflex, but deflating with a cuff pressure guage can increase the incidence of postoperative hoarseness.

Trial Registration: Chinese Clinical Trial Registry, identifier: ChiCTR2100054089, Date: 08/12/2021.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9903553PMC
http://dx.doi.org/10.1186/s12871-023-02003-5DOI Listing

Publication Analysis

Top Keywords

tracheal tube
20
tube cuff
20
cuff deflation
20
cough reflex
20
patients group
12
group underwent
12
underwent tracheal
12
deflation cough
8
reflex extubation
8
incidence cough
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!