Background: Although ceramic-on-ceramic (CoC) bearings result in the lowest wear rate of any bearing combination, postoperative squeaking remains worrisome. However, data concerning squeaking in long-term follow-up studies are still lacking, especially for fourth-generation CoC THA.
Questions/purposes: (1) After keeping the prosthesis in place for 10 years, what percentage of patients treated with fourth-generation CoC THA implants report squeaking, and are there points in time when squeaking occurs more frequently? (2) What are the characteristics, association with hip function, and factors associated with squeaking? (3) Can we create a nomogram that characterizes a patient's odds of experiencing squeaking based on the factors associated with it?
Methods: Between January 2009 and December 2011, 1050 patients received primary THAs at our institution, 97% (1017) of whom received fourth-generation CoC THAs because this was the preferred bearing during this period. Of the 1017 eligible patients, 5% (54) underwent THAs performed by low-volume surgeons, 3% (30) were implanted with cemented prostheses, 2% (22) died, 1% (10) were immobile, 1% (six) underwent revision surgery, and 17% (169) were lost to follow-up before 10 years, leaving 726 patients for analysis here at a mean of 11 ± 1 years. In the study cohort, 64% (464) were male and 36% (262) were female, with a mean age of 44 ± 13 years at primary THA. We extracted data about articular noise from follow-up records in our institutional database and used a newly developed questionnaire to ascertain the percentage of patients who reported squeaking at the latest follow-up interval. Although not validated, the questionnaire was modeled on previous studies on this topic. The longitudinal pattern for squeaking was explored to find timepoints when squeaking occurs more frequently. Based on the questionnaire data, we calculated the percentages of frequent, reproducible, and avoidable squeaking. Hip function was evaluated with the Harris Hip Score and WOMAC score and compared between the squeaking and nonsqueaking groups. Factors associated with squeaking, which were examined in a multivariate analysis, were used to develop a nomogram.
Results: At 10 years, 16% (116 of 726) of patients reported squeaking. Two squeaking peaks were determined, at 0 to 1 year and 8 to 10 years. Frequent, reproducible, and avoidable squeaking accounted for 42% (36 of 86), 20% (17 of 86), and 41% (35 of 86), respectively. The mean Harris Hip Score (93 ± 4 versus 94 ± 5; p = 0.81) and WOMAC score (16 ± 13 versus 15 ± 13; p = 0.23) did not differ between patients with squeaking and those without. After controlling for potential confounding variables such as etiology and head offset, we found that patients younger than 46 years (odds ratio 2.5 [95% confidence interval 1.5 to 5.0]; p < 0. 001), those who were male (OR 2.0 [95% CI 1.1 to 3.5]; p = 0.04), those having a total flexion and extension arc of less than 50° (OR 2.0 [95% CI 1.2 to 3.3]; p = 0.02), and those with the Corail hip implant (OR 4.1 [95% CI 2.1 to 7.7]; p < 0. 001) were more likely to report squeaking. We created a nomogram that can be used at the point of care that can help clinicians identify patients at a higher risk of experiencing squeaking; this nomogram had good performance (area under the receiver operating characteristic curve of 77%).
Conclusion: As a potential late complication, squeaking after fourth-generation CoC THA is of concern and may be related to increased stripe wear. We recommend that surgeons use this nomogram to assess the odds of squeaking before selecting a bearing, especially in patients at high risk, to facilitate shared decision-making and improve patient satisfaction. Future external validation of the model is still needed to enhance its applicability.Level of Evidence Level III, therapeutic study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10263255 | PMC |
http://dx.doi.org/10.1097/CORR.0000000000002573 | DOI Listing |
Arch Orthop Trauma Surg
December 2024
HIBA Hip Surgery Unit, Institute of Orthopaedics "Carlos E. Ottolenghi", Italian Hospital of Buenos Aires, Buenos Aires, Argentina.
Purpose: This study aimed to assess the long-term results of THA patients who received a cementless short stem regarding clinical outcomes, bone changes, complications, and incidence of femoral revision.
Methods: A retrospective evaluation of the first 100 THA employing a type 2B cementless stem (Mini hip stem, Corin, Cirencester, United Kingdom) by the same surgeon at one institution. We only include patients with 18 years or more, and with a minimum follow up of 8 years.
HSS J
March 2024
Department of Orthopaedic Surgery, University Orthopaedic, Hand and Reconstructive Microsurgery Cluster, National University Health System, Singapore.
Background: To date, the occurrence of unusual squeaking noises during shoulder movements following shoulder arthroscopic surgeries have been minimally reported.
Purpose: The aim of this study was to report the incidence, natural history, possible risk factors and functional outcomes of patients who reported to have squeaking noises following shoulder arthroscopic procedures.
Methods: In this 2-year case-control study, all patients who underwent arthroscopic shoulder in a single institution were included.
Front Neurosci
October 2024
Hurley Laboratory, Department of Biology, Indiana University, Bloomington, IN, United States.
Variation in the mutual responsiveness of social partners to each other can be reflected in behavioral suites that covary with neural activity in ways that track the salience or valence of interactions. Juvenile social isolation alters social behavior and neural activity during social interaction, but whether and how it alters the covariation between behavior and neural activity has not been as well explored. To address this issue, four classes of experimental subjects: isolated males, socially housed males, isolated females, and socially housed females, were paired with an opposite-sex social partner that had been socially housed.
View Article and Find Full Text PDFSensors (Basel)
August 2024
AI & Mechanical System Center, Institute for Advanced Engineering, Youngin-si 17180, Republic of Korea.
This study researched the prediction of the BSR noise evaluation quantitative index, Loudness N10, for sound sources with noise using statistics and machine learning. A total of 1170 data points was obtained from 130 automotive seats measured at 9-point positions, with Gaussian noise integrated to construct synthetic sound data. Ten physical quantities related to sound quality and sound pressure were used and defined as dB and fluctuation strength, considering statistical characteristics and Loudness N10.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!