Bioimpedance basics and phase angle fundamentals.

Rev Endocr Metab Disord

Department of Procurement and Clinical Engineering, Central Denmark Region, Aarhus, Denmark.

Published: June 2023

Measurement of phase angle using bioimpedance analysis (BIA) has become popular as an index of so-called "cellular health". What precisely is meant by this term is not always clear but strong relationships have been found between cellular water status (the relative amounts of extra- and intracellular water), cell membrane integrity and cellular mass. Much of the current research is empirical observation and frequently pays little regard to the underlying biophysical models that underpin the BIA technique or attempts to provide mechanistic explanations for the observations. This brief review seeks to provide a basic understanding of the electrical models frequently used to describe the passive electrical properties of tissues with particular focus on phase angle. In addition, it draws attention to some practical concerns in the measurement of phase angle and notes the additional understanding that can be gained when phase angle are obtained with bioimpedance spectroscopy (BIS) rather than single frequency BIA (SFBIA) along with the potential for simulation modelling.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10140124PMC
http://dx.doi.org/10.1007/s11154-022-09780-3DOI Listing

Publication Analysis

Top Keywords

phase angle
20
measurement phase
8
angle bioimpedance
8
phase
5
angle
5
bioimpedance basics
4
basics phase
4
angle fundamentals
4
fundamentals measurement
4
bioimpedance analysis
4

Similar Publications

Influence of Geometric Parameters on The Hemodynamic Characteristics of The Vertebral Artery.

J Biomech Eng

January 2025

State Key Laboratory of Clean Energy Utilization, Zhejiang University, Yuquan Campus, 38 Zheda Road, Hangzhou 310027, Zhejiang, China; Shanghai Institute for Advanced Study of Zhejiang University, Zhangjiang Guochuang Center phase, No.799, Dangui Road, Shanghai 200120, China.

The carotid and vertebral arteries are principal conduits for cerebral blood supply and are common sites for atherosclerotic plaque formation. To date, there has been extensive clinical and hemodynamic reporting on carotid arteries; however, studies focusing on the hemodynamic characteristics of the vertebral artery (VA) are notably scarce. This article presents a systematic analysis of the impact of VA diameter and the angle of divergence from the subclavian artery (SA) on hemodynamic properties, facilitated by the construction of an idealized VA geometric model.

View Article and Find Full Text PDF

Among expanding discoveries of quantum phases in moiré superlattices, correlated insulators stand out as both the most stable and most commonly observed. Despite the central importance of these states in moiré physics, little is known about their underlying nature. Here, we use pump-probe spectroscopy to show distinct time-domain signatures of correlated insulators at fillings of one (ν = -1) and two (ν = -2) holes per moiré unit cell in the angle-aligned WSe/WS system.

View Article and Find Full Text PDF

Introduction of non-DLVO forces by nonionic surfactants brings about fascinating changes in the phase behavior of silica nanosuspensions. We show here that alterations in the interaction and wetting properties of negatively charged silica nanoparticles (Ludox® LS) in the presence of polyethylene oxide-polypropylene oxide-polyethylene oxide-based triblock copolymers called Pluronics lead to the formation of stable o/w Pickering emulsions and interparticle attraction-induced thermoresponsive liquid-liquid phase separations. The results make interesting comparisons with those reported for Ludox® TM nanosuspensions comprising larger silica nanoparticles.

View Article and Find Full Text PDF

Background: This study aimed to assess how knee savers (KSs) and knee pads (KPs) alleviate risks of knee musculoskeletal disorders (MSDs) among roofers during various phases of shingle installation. These phases encompass (1) reaching for shingles, (2) placing shingles, (3) grabbing a nail gun, (4) moving to the first nailing position, (5) nailing shingles, (6) replacing the nail gun, and (7) returning to an upright position.

Methods: In a laboratory setting, nine male participants simulated the shingle installation task on a slope-adjustable roof platform (0°, 15°, and 30° slopes) under four intervention conditions: no intervention (NO); with KPs only (KP); with KSs only (KS); and with both KPs and KSs (BO).

View Article and Find Full Text PDF

Aerodynamic analysis of complex flapping motions based on free-flight biological data.

Bioinspir Biomim

January 2025

School of Mechatronical Engineering, Beijing Institute of Technology, 5 South Zhonghuancun, Haidian District, Beijing 100081, Beijing, 100081, CHINA.

The wings of birds contain complex morphing mechanisms that enable them to perform remarkable aerial maneuvers. Wing morphing is often described using five wingbeat motion parameters: flapping, bending, folding, sweeping, and twisting. However, owing to a lack of real bird flight data, in-depth studies on the aerodynamic properties of these coupled motions remain scarce.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!