Methane Venting at Cold Heavy Oil Production with Sand (CHOPS) Facilities Is Significantly Underreported and Led by High-Emitting Wells with Low or Negative Value.

Environ Sci Technol

Energy & Emissions Research Laboratory, Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, Ontario Canada, K1S 5B6.

Published: February 2023

AI Article Synopsis

  • A study analyzed methane venting from CHOP(S) facilities in Saskatchewan, using both airborne LiDAR and on-site measurements, highlighting a strong correlation between the two methods.
  • Findings revealed that actual methane emissions were nearly four times higher than reported, with 80% attributed to casing gas venting, indicating possible shortcomings in current regulations.
  • The research underscored the need for improved tracking of emissions, pointing out that about one-third of methane comes from environmentally marginal wells, which may undermine the economic viability of oil production due to carbon pricing implications.

Article Abstract

Cold Heavy Oil Production with or without Sand, CHOP(S), facilities produce a significant portion of Canada's conventional oil. Methane venting from single-well CHOPS facilities in Saskatchewan, Canada was measured (i) using Bridger Photonics' airborne Gas Mapping LiDAR (GML) at 962 sites and (ii) on-site using an optical mass flux meter (VentX), ultrasonic flow meter, and QOGI camera at 11 sites. The strong correlation between ground measurements and airborne GML supported subsequent detailed analysis of the aerial data and to our knowledge is the first study to directly test the ability of airplane surveys to accurately reproduce mean emission rates of unsteady sources. Actual methane venting was found to be nearly four times greater than the industry-reported levels used in emission inventories, with ∼80% of all emissions attributed to casing gas venting. Further analysis of site-total emissions revealed potential gaps in regulations, with 14% of sites appearing to exceed regulated limits while accounting for 61% of measured methane emissions. Finally, the concept of marginal wells was adapted to consider the inferred cost of methane emissions under current carbon pricing. Results suggest that almost a third of all methane is emitted from environmentally marginal wells, where the inferred methane cost negates the value of the oil produced. Overall, the present results illustrate the importance of independent monitoring, reporting, and verification (MRV) to ensure accuracy in reporting and regulatory compliance, and to ensure mitigation targets are not foiled by a collection of disproportionately high-emitting sites.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979599PMC
http://dx.doi.org/10.1021/acs.est.2c06255DOI Listing

Publication Analysis

Top Keywords

methane venting
12
chops facilities
12
cold heavy
8
heavy oil
8
oil production
8
production sand
8
sand chops
8
methane emissions
8
marginal wells
8
methane
7

Similar Publications

Hydrothermal vents emit hot fluids enriched in energy sources for microbial life. Here, we compare the ecological and biogeochemical effects of hydrothermal venting of two recently discovered volcanic seamounts, Polaris and Aurora of the Gakkel Ridge, in the ice-covered Central Arctic Ocean. At both sites, persistent hydrothermal plumes increased up to 800 m into the deep Arctic Ocean.

View Article and Find Full Text PDF

Chemical Antiquity in Metabolism.

Acc Chem Res

August 2024

Institute of Molecular Evolution, Faculty of Mathematics and Natural Sciences, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany.

ConspectusLife is an exergonic chemical reaction. The same was true when the very first cells emerged at life's origin. In order to live, all cells need a source of carbon, energy, and electrons to drive their overall reaction network (metabolism).

View Article and Find Full Text PDF
Article Synopsis
  • Leakage from oil and gas wells contributes to methane emissions and can contaminate groundwater, making well integrity crucial for environmental protection.
  • Incomplete industry reporting in Canada leads to discrepancies in government emissions inventories, affecting estimates of wellbore methane emissions in British Columbia and Alberta, which range from 23 to 176 kilotons.
  • The study highlights the underreporting of leaks, recommends better data tracking and testing methods, and suggests using optical gas imaging cameras to enhance monitoring efforts.
View Article and Find Full Text PDF

Anaerobic oxidation of methane driven by different electron acceptors: A review.

Sci Total Environ

October 2024

Fujian Provincial Key Laboratory of Water Cycling and Eco-Geological Processes, Xiamen 361021, China; Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences, Shijiazhuang 050061, China. Electronic address:

Methane, the most significant reduced form of carbon on Earth, acts as a crucial fuel and greenhouse gas. Globally, microbial methane sinks encompass both aerobic oxidation of methane (AeOM), conducted by oxygen-utilizing methanotrophs, and anaerobic oxidation of methane (AOM), performed by anaerobic methanotrophs employing various alternative electron acceptors. These electron acceptors involved in AOM include sulfate, nitrate/nitrite, humic substances, and diverse metal oxides.

View Article and Find Full Text PDF

Electrochemical Generation of Hydroxide and Hydrogen Peroxide for Hydrolysis of Sulfuryl Fluoride Fumigant.

J Agric Food Chem

July 2024

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States.

The post-harvest fumigant, sulfuryl fluoride (SOF), is a >1000-fold more potent greenhouse gas than carbon dioxide and methane. Pilot studies have shown that SOF fumes vented from fumigation chambers can be captured and hydrolyzed by hydroxide (OH) and hydrogen peroxide (HO) at pH ∼ 12 in a scrubber, producing SO and F as waste salts. To reduce the costs and challenges associated with purchasing and mixing these reagents onsite, this study evaluates the electrochemical generation of OH and HO within spent scrubbing solution, taking advantage of the waste SO and F as free sources of electrolyte.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!