Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Accurate needle placement into the target point is critical for ultrasound interventions like biopsies and epidural injections. However, aligning the needle to the thin plane of the transducer is a challenging issue as it leads to the decay of visibility by the naked eye. Therefore, we have developed a CNN-based framework to track the needle using the spatiotemporal features of the speckle dynamics.
Methods: There are three key techniques to optimize the network for our application. First, we used Gunnar-Farneback (GF) as a traditional motion field estimation technique to augment the model input with the spatiotemporal features extracted from the stack of consecutive frames. We also designed an efficient network based on the state-of-the-art Yolo framework (nYolo). Lastly, the Assisted Excitation (AE) module was added at the neck of the network to handle the imbalance problem.
Results: Fourteen freehand ultrasound sequences were collected by inserting an injection needle steeply into the Ultrasound Compatible Lumbar Epidural Simulator and Femoral Vascular Access Ezono test phantoms. We divided the dataset into two sub-categories. In the second category, in which the situation is more challenging and the needle is totally invisible, the angle and tip localization error were 2.43 ± 1.14° and 2.3 ± 1.76 mm using Yolov3+GF+AE and 2.08 ± 1.18° and 2.12 ± 1.43 mm using nYolo+GF+AE.
Conclusion: The proposed method has the potential to track the needle in a more reliable operation compared to other state-of-the-art methods and can accurately localize it in 2D B-mode US images in real time, allowing it to be used in current ultrasound intervention procedures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-022-02812-y | DOI Listing |