A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Image quality assessment in low-dose COVID-19 chest CT examinations. | LitMetric

Image quality assessment in low-dose COVID-19 chest CT examinations.

Acta Radiol

Diagnostic and Interventional Radiology Department, AP-HP Paris Saclay University, Bicêtre Hospital, Le Kremlin-Bicêtre, Le Kremlin Bicêtre, France.

Published: January 2024

Background: Low-dose thoracic protocols were developed massively during the COVID-19 outbreak.

Purpose: To study the impact on image quality (IQ) and the diagnosis reliability of COVID-19 low-dose chest computed tomography (CT) protocols.

Material And Methods: COVID-19 low-dose protocols were implemented on third- and second-generation CT scanners considering two body mass index (BMI) subgroups (<25 kg/m and >25 kg/m). Contrast-to-noise ratios (CNR) were compared with a Catphan phantom. Next, two radiologists retrospectively assessed IQ for 243 CT patients using a 5-point Linkert scale for general IQ and diagnostic criteria. Kappa score and Wilcoxon rank sum tests were used to compare IQ score and CTDI between radiologists, protocols, and scanner models.

Results: In vitro analysis of Catphan inserts showed in majority significantly decreased CNR for the low dose versus standard acquisition protocols on both CT scanners. However, in vivo, there was no impact on the diagnosis: sensitivity and specificity were ≥0.8 for all protocols and CT scanners. The third-generation scanner involved a significantly lower dose compared to the second-generation scanner (CTDI of 1.8 vs. 2.6 mGy for BMI <25 kg/m and 3.3 vs. 4.6 mGy for BMI >25 kg/m). Still, the third-generation scanner showed a significantly higher IQ with the low-dose protocol compared to the second-generation scanner (30.9 vs. 28.1 for BMI <25 kg/m and 29.9 vs. 27.8 for BMI >25 kg/m). Finally, the two radiologists had good global inter-reader agreement (kappa ≥0.6) for general IQ.

Conclusion: Low-dose protocols provided sufficient IQ independently of BMI subgroups and CT models without any impact on diagnosis reliability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9905706PMC
http://dx.doi.org/10.1177/02841851231153797DOI Listing

Publication Analysis

Top Keywords

image quality
8
diagnosis reliability
8
covid-19 low-dose
8
low-dose protocols
8
bmi subgroups
8
protocols scanners
8
impact diagnosis
8
third-generation scanner
8
compared second-generation
8
second-generation scanner
8