Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Natalizumab is a highly effective monoclonal antibody for the treatment of multiple sclerosis (MS), which can diffuse in different anatomical compartments, including cerebrospinal fluid (CSF) and milk.
Objectives: Starting from incidental detection of natalizumab in the CSF of MS patients, the objective of this study was to develope a flow-cytometry-based assay and apply it to quantify natalizumab in body fluids, including milk collected from nursing patients over 180 days and in patients with neutralizing antibodies against natalizumab.
Methods: CSF, milk and sera samples from patients with multiple sclerosis were tested by flow-cytometry for binding to a VLA-4 expressing cell line or to a control cell line. A standard curve was prepared by incubating the same cells with natalizumab at 50 μg/ml and serially diluted to 0.005 ng/ml. Binding specificity was confirmed using an anti-natalizumab neutralizing antibody.
Results: Our assay was sensitive enough to detect natalizumab in CSF, with a lower detection limit of 1.5 ng/ml. Neutralizing antibodies against natalizumab inhibited binding to the cell line. In breastmilk, the peak concentration was observed during the first 2 weeks after infusion and the average concentration over the observation time was 173.3 ng/ml, with a trend toward increased average milk concentration over subsequent administrations.
Conclusion: Routine use of such an assay would enable a better understanding of the safety of therapeutic antibody administration during pregnancy and lactation.