In the last years, LA-ICP-MS has become an attractive technique for analyzing solid samples from various research fields. However, application in material science is often hampered by the limited availability of appropriate certified reference materials, which are a precondition for accurate quantification. Thus, frequently in-house prepared standards are used, which match the sample's composition and include all elements of interest at the required concentration levels. However, preparing and characterizing such standards is often labor-intensive and time-consuming. This work proposes a new approach for the fabrication of matrix-matched standards based on the concept of standard addition. In the first step, the analytes of interest are homogeneously deposited onto the sample surface using liquid standards and a spraying device. For analysis, the generated thin layer is ablated simultaneously with the underlying sample. Thereby deviations in the ablation process and particle transport can be avoided. It could be shown that the developed method is highly versatile and could be easily adapted to the actual needs. Using silicon, silicon carbide, copper, aluminum, and glass as a matrix, excellent linear correlations between observed signal intensities and deposited amounts were found for the elements Zn, Ag, In, and Pb (R - values greater than 0.99). The method was applied to determine the content of sulfur, zinc, silver, indium, and lead in a commercial Kapton® polyimide film. The obtained results could be verified based on the homogeneously distributed sulfur by conventional liquid ICP-MS analysis after sample digestion, showing similar precision and accuracy. Lead was found to show a very inhomogeneous distribution in the Kapton® film, with concentration below the LOD at most measured locations and irregularly occurring spots with significantly higher concentrations. Finally, a quantitative depth profile of sulfur in a Kapton® film has been measured to assess the uptake of SO after a weathering experiment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.124305DOI Listing

Publication Analysis

Top Keywords

matrix-matched standards
8
standard addition
8
liquid standards
8
kapton® film
8
standards
6
versatile approach
4
approach preparation
4
preparation matrix-matched
4
standards la-icp-ms
4
la-icp-ms analysis
4

Similar Publications

Determination and validation of polycyclic aromatic hydrocarbons (PAH4) in katsuobushi, plant-based food supplements, and cocoa bean shells using GC-MS/MS.

J Food Drug Anal

December 2024

Division of Research and Analysis, Taiwan Food and Drug Administration, Ministry of Health and Welfare, No.161-2, Kunyang St, Nangang District, Taipei City 11561, Taiwan, R.O.C.

Polycyclic aromatic hydrocarbons (PAHs) are primarily generated through the incomplete combustion or pyrolysis of organic materials in various industrial processes. Foods may become contaminated with environmental PAHs found in air, soil, or water, or through industrial food processing methods such as smoking, roasting, drying, and grilling. The Ministry of Health and Welfare in Taiwan has established maximum levels for benzo[a]pyrene (BaP) and indicative values for BaP as well as PAH4 (the sum of benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene) in foods as operational guidelines.

View Article and Find Full Text PDF
Article Synopsis
  • The study developed a portable mass spectrometry technique for accurately measuring tirofiban drug concentrations in blood to enhance patient safety and treatment efficacy.
  • The method identified a significant parent ion peak for tirofiban and optimized various parameters, achieving a limit of detection (LOD) and limit of quantification (LOQ) of 10.1 and 33.7 μg·L, respectively.
  • Although the technique faced some challenges from blood sample matrix effects, it successfully detected tirofiban in 10 out of 12 clinical samples, demonstrating the need for further optimization and validation to boost sensitivity and stability.
View Article and Find Full Text PDF

Recently, an instrumental analysis using LC-MS/MS has been developed and validated for paralytic shellfish toxins (PSTs) and tetrodotoxin (TTX) in bivalve molluscs in Japanese domestic and overseas. The method for 11 PSTs and TTX in scallops was validated in accordance with a previous report and CODEX-STAN. The samples were prepared by adding the standard mixture of PSTs and TTX to scallop (Patinopecten yessoensis) homogenates, extracted with 1% acetic acid and then cleaned up using an ENVI-Carb (250 mg/3 mL) cartridge.

View Article and Find Full Text PDF

Preparation of REE-doped CaF single crystals for accurate determination of REE concentrations in CaF crystals via UV-LA-ICP-MS.

Talanta

December 2024

Key Laboratory of Testing and Tracing of Rare Earth Products, State Administration for Market Regulation, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China; Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China. Electronic address:

Accurate determination of rare earth element (REE) concentrations in CaF crystals using UV-LA-ICP-MS is important but challenging due to the lack of matrix-matched reference materials. In this study, a REE-doped CaF single crystal (CaF-05), prepared via the Bridgman-Stockbarger technique, was systematically characterized to assess its optical properties, homogeneity, and stability. Analyses using portable laser irradiation, UV-vis spectroscopy, back scatter electron (BSE) imaging, and cathodoluminescence (CL) demonstrated that the crystal possesses high optical quality and exhibits distinct optical adsorption properties compared to the silicate reference material NIST SRM 610.

View Article and Find Full Text PDF

Caine-based anesthetics are frequently used in the production and transportation of aquatic products, but residues in fish threaten human health. A rapid, sensitive, and effective method was developed for detecting caine-based anesthetics and their metabolite residues in fish using ultra-high performance liquid chromatography-tandem mass spectrometry coupled with a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. The sample was extracted with 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!