A 37-year-old man with previous heart transplantation for dilated cardiomyopathy underwent screening for malignancy under posttransplantation immunosuppression. 18 F-FDG PET/CT revealed uptake in 2 peritoneal sites of the pericardium that corresponded to the insertion sites of a left ventricular assist device that was used before transplantation. Additional abnormal uptake in the right axillary artery, aortic arch, and left femoral artery corresponded to the insertion sites for arterial inflow during cardiopulmonary bypass. Knowledge that FDG accumulation may occur at the insertion sites of an extracorporeal-circulation device enables unnecessary tests to be avoided.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9988220PMC
http://dx.doi.org/10.1097/RLU.0000000000004580DOI Listing

Publication Analysis

Top Keywords

insertion sites
12
f-fdg pet/ct
8
heart transplantation
8
ventricular assist
8
assist device
8
corresponded insertion
8
sites
5
pet/ct imaging
4
imaging post
4
post heart
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?