Effects of Nitrurized Titanium on Microhardness and Human Dental Pulp Stem Cell Adhesion and Differentiation.

J Long Term Eff Med Implants

Interdisciplinary Research Laboratory (LII), Nanostructures and Biomaterials Area, National School of Higher Studies (ENES) León Unit, Predio el Saucillo y el Potrero, Comunidad de los Tepetates, El Potrero, 37684 León, Mexico.

Published: February 2023

To compare the Vickers microhardness, surface roughness, initial adhesion, and osteogenic differentiation on titanium (Ti) and nitrurized titanium (NTi) plates were treated by UV irradiation and chitosan. Each plate was subjected to Vickers hardness with a pressure of 2.9 N for 10 seconds and roughness evaluation by atomic force microscope (AFM) analysis. Three groups of each type of plates were tested: control (C), ultraviolet irradiation (UV), and chitosan (Q). The UV group was exposed to UV-irradiation for 20 min at 253.7 nm (52 μW/cm2). The Q group was coated with 1% chitosan, and the C group had no treatment. The osteoblasts (2 × 106 cells/mL) were inoculated in each group for 60 min and their viability was determined by the MTT bioassay. Osteogenic differentiation was performed over 4 weeks and determined by alizarin red staining. The mean was analyzed with the Shapiro-Wilks, Kruskall-Wallis, and Mann-Whitney U tests of normality (n = 9/gp). The NTi plates hardness (125.1 ± 4.01 HV) was higher (P = 0.026) than the Ti plates (121.3 ± 2.23 HV). The surface topography was: NTi (Ra = 0.098 μm) and Ti (Ra = 0.212 μm). The quantification of cell adhesion was: Ti + Q = 123 ± 4.9% (P < 0.05) < NTi + Q = 107 ± 3.3% < Ti = 100 ± 10.7% < NTi = 72 ± 6.8% < NTi + UV = 71 ± 4.4% < Ti + UV = 69 ± 3.5%, regardless the plates, the presence of chitosan induce a faster osteogenic differentiation. The Ti + Q plates tested the highest cell attachment and osteogenic adhesion suggesting their potential use of chitosan for cell-implant interaction.

Download full-text PDF

Source
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2022044424DOI Listing

Publication Analysis

Top Keywords

osteogenic differentiation
12
nitrurized titanium
8
cell adhesion
8
nti plates
8
irradiation chitosan
8
plates tested
8
chitosan group
8
nti
6
plates
6
chitosan
5

Similar Publications

The therapeutic potential of extracellular vesicles (EVs) in bone regeneration is noteworthy; however, their clinical application is impeded by low yield and limited efficacy. This study investigated the effect of low-intensity pulsed ultrasound (LIPUS) on the therapeutic efficacy of EVs derived from periodontal ligament stem cells (PDLSCs) and preliminarily explored its mechanism. PDLSCs were cultured with osteogenic media and stimulated with or without LIPUS, and then EVs and LIPUS-stimulated EVs (L-EVs) were isolated separately.

View Article and Find Full Text PDF

This study assessed the novel concept that osteoclast-derived Grem1 has regulatory functions in the skeletal response to calcium stress using an osteoclastic Grem1 conditional knockout (cKO) mouse model. The calcium stress was initiated by feeding cKO mutants and wildtype (WT) littermates a calcium-deficient diet for 2 weeks. Deletion of Grem1 in mature osteoclasts did not affect developmental bone growth nor basal bone turnover.

View Article and Find Full Text PDF

Cellulose-mediated mechanical property tuning in small intestinal submucosal matrix to enhance stem cell osteogenic differentiation.

Int J Biol Macromol

January 2025

School of Life Sciences and Health Engineering, Jiangnan University, Wuxi 214122, China; GWDC Kunshan Company, Kunshan 215337, China; Jingkun Chemistry Company, Kunshan 215337, China. Electronic address:

Natural extracellular matrices (ECM) provide a more accurate simulation of the cellular growth environment, making them excellent substrate materials for in vitro cell culture. The porcine small intestinal submucosa (SIS) is one of the most widely used natural ECM that display superior bioactivity. However, decellularization operations often result in fiber breakage and failure to recover mechanical strength in the SIS.

View Article and Find Full Text PDF

Mechanical loading plays a pivotal role in regulating bone anabolic processes. Understanding the optimal mechanical loading parameters for cellular responses is critical for advancing strategies in orthopedic bioreactor-based bone tissue engineering. This study developed a poly (sorbitol sebacate) (PSS) filmscaffold with a sorbitol-to-sebacic acid molar ratio of 1:4.

View Article and Find Full Text PDF

Antibacterial and osteogenic gain strategy on titanium surfaces for preventing implant-related infections.

Colloids Surf B Biointerfaces

December 2024

College of Chemical Engineering, Xinjiang Normal University, 102 Xinyi Road, Urumqi 830054, P.R. China. Electronic address:

Infection and insufficient osseointegration are the primary factors leading to the failure of titanium-based implants. Surface coating modifications that combine both antibacterial and osteogenic properties are commonly employed strategies. However, the challenge of achieving rapid antibacterial action and consistent osteogenesis with these coatings remains unresolved.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!