Background: Short-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.

Methods: Native femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5°, 10°, 15°, 20°, 25°, and 30°) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.

Results: The native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5° stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.

Conclusions: Stress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5° stem minimizes the stress shielding effect and presents a more bionic mechanical performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893650PMC
http://dx.doi.org/10.1186/s12891-023-06205-3DOI Listing

Publication Analysis

Top Keywords

bionic reconstruction
12
hip arthroplasty
12
reconstruction tension
8
tension trabeculae
8
short-stem hip
8
finite element
8
load transfer
8
stress shielding
8
proximal femur
8
tension screw
8

Similar Publications

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.

View Article and Find Full Text PDF

Single-crystal Au(111), renowned for its chemically inert surface, long-range "herringbone" reconstruction, and high electrical conductivity, has long served as an exemplary template in diverse fields, , crystal epitaxy, electronics, and electrocatalysis. However, commercial Au(111) products are high-priced and limited to centimeter sizes, largely restricting their broad applications. Herein, a low-cost, high-reproducible method is developed to produce 4 in.

View Article and Find Full Text PDF

Bionic Modeling Study on the Landing Mechanism of Flapping Wing Robot Based on the Thoracic Legs of Purple Stem Beetle, .

Biomimetics (Basel)

January 2025

Robotics and Microsystems Center, College of Mechanical and Electrical Engineering, Soochow University, Suzhou 215021, China.

Flapping wing micro aerial vehicles (FWMAVs) are recognized for their significant potential in military and civilian applications, such as military reconnaissance, environmental monitoring, and disaster rescue. However, the lack of takeoff and landing capabilities, particularly in landing behavior, greatly limits their adaptability to the environment during tasks. In this paper, the purple stem beetle (), a natural flying insect, was chosen as the bionic research object.

View Article and Find Full Text PDF

Introduction: Artificial vascular scaffolds can mimic the structure of natural blood vessels and replace the damaged vessels by implanting them at the injury site to perform the corresponding functions. Electrospinning technology can perfectly combine biological signals and topographical cues to synergistically induce directed cell migration and growth.

Methods: In this study, poly (caprolactone) (PCL) nanofibers, PCL nanofibers uniformly coated with the extracellular matrix derived from endothelial cells (ECd), and bi-directional linear gradient ECd-coated PCL nanofibers were prepared by electrospinning and electrospray techniques to evaluate their effects on the proliferation and migration of Human umbilical vein endothelial cells (HUVECs) and rapid endothelialization.

View Article and Find Full Text PDF

With precise control of smart materials deformation in time dimension, doctors can customize orthopedic implants. This review focuses on the advances of 4D printing technology in orthopedics, including its applications in bone repair and reconstruction, personalized treatment, and drug delivery. 4D printing enables the creation of bionic scaffolds and fixation devices for bone repair, customized implants matching patients' conditions for personalized treatment, and specific carriers for accurate drug release and delivery, which together contribute to accelerating bone healing, providing exclusive treatments, enhancing therapeutic effects and reducing side effects, thus helping improve orthopedic medicine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?