A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated localization of the medial clavicular epiphyseal cartilages using an object detection network: a step towards deep learning-based forensic age assessment. | LitMetric

Background: Deep learning is a promising technique to improve radiological age assessment. However, expensive manual annotation by experts poses a bottleneck for creating large datasets to appropriately train deep neural networks. We propose an object detection approach to automatically annotate the medial clavicular epiphyseal cartilages in computed tomography (CT) scans.

Methods: The sternoclavicular joints were selected as structure-of-interest (SOI) in chest CT scans and served as an easy-to-identify proxy for the actual medial clavicular epiphyseal cartilages. CT slices containing the SOI were manually annotated with bounding boxes around the SOI. All slices in the training set were used to train the object detection network RetinaNet. Afterwards, the network was applied individually to all slices of the test scans for SOI detection. Bounding box and slice position of the detection with the highest classification score were used as the location estimate for the medial clavicular epiphyseal cartilages inside the CT scan.

Results: From 100 CT scans of 82 patients, 29,656 slices were used for training and 30,846 slices from 110 CT scans of 110 different patients for testing the object detection network. The location estimate from the deep learning approach for the SOI was in a correct slice in 97/110 (88%), misplaced by one slice in 5/110 (5%), and missing in 8/110 (7%) test scans. No estimate was misplaced by more than one slice.

Conclusions: We demonstrated a robust automated approach for annotating the medial clavicular epiphyseal cartilages. This enables training and testing of deep neural networks for age assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10085900PMC
http://dx.doi.org/10.1007/s00414-023-02958-7DOI Listing

Publication Analysis

Top Keywords

medial clavicular
20
clavicular epiphyseal
20
epiphyseal cartilages
20
object detection
16
detection network
12
age assessment
12
deep learning
8
deep neural
8
neural networks
8
slices training
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!