A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison in Repetitions to Failure Between Concentric-Only and Eccentric-Only Dumbbell Arm Curl Exercise at Four Different Relative Intensities. | LitMetric

Comparison in Repetitions to Failure Between Concentric-Only and Eccentric-Only Dumbbell Arm Curl Exercise at Four Different Relative Intensities.

J Strength Cond Res

Centre for Human Performance, School of Medical and Health Sciences, Edith Cowan University, Joondalup, Western Australia, Australia.

Published: September 2023

Shibata, K, Yamaguchi, T, Takizawa, K, and Nosaka, K. Comparison in repetitions to failure between concentric-only and eccentric-only dumbbell arm curl exercise at four different relative intensities. J Strength Cond Res 37(9): 1754-1760, 2023-The repetitions to failure (RF) were compared between concentric-only (CON) and eccentric-only (ECC) arm curl exercise for different intensities based on CON and ECC 1 repetition maximum (1RM), respectively, with 2 different inter-repetition rests. Sixteen healthy male, university students (19-22 years) participated in 6 sessions. In sessions 1 and 2, CON and ECC 1RM strength were determined. In sessions 3 to 6, CON and ECC dumbbell arm curl exercises were performed until momentary failure at the intensity of either 70, 80, 90 or 95% of CON and ECC 1RM, respectively, with the inter-repetition rest of 3 seconds (R3) for one arm and 6 seconds (R6) for the other arm in a pseudo-randomized order. A significant ( p < 0.01) muscle contraction type × intensity interaction effect was evident for both R3 and R6 conditions. RF was greater ( p < 0.01) in ECC than in CON at 70% (34.2 ± 13.3 vs 20.9 ± 5.4), 80% (22.0 ± 6.7 vs 11.6 ± 2.7), 90% (10.1 ± 3.1 vs 5.2 ± 1.3), and 95% (6.8 ± 2.1 vs 2.7 ± 0.8) for R3. RF was also greater ( p < 0.01) for ECC than for CON at 80% (24.5 ± 8.1 vs 15.6 ± 3.6), 90% (10.8 ± 2.8 vs 7.2 ± 1.8) and 95% (6.7 ± 2.4 vs 3.9 ± 1.5) for R6, with greater ( p < 0.05) RF for R6 than R3. Significant ( p < 0.01) correlations in RF were evident between CON and ECC for R3 ( r = 0.86) and R6 ( r = 0.76). Equations to estimate 1RM were derived for CON and ECC at R3 and R6 (e.g., ECC 1RM = Load × 110.0/[110.5-RF] for R3). These results suggest that fatigue is less in ECC than in CON performed at the same relative intensity.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000004470DOI Listing

Publication Analysis

Top Keywords

con ecc
24
arm curl
16
repetitions failure
12
dumbbell arm
12
curl exercise
12
ecc 1rm
12
ecc con
12
ecc
11
con
10
comparison repetitions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!