We report the 2018 self-consistent values of constants and conversion factors of physics and chemistry recommended by the Committee on Data of the International Science Council. The recommended values can also be found at physics.nist.gov/constants. The values are based on a least-squares adjustment that takes into account all theoretical and experimental data available through 31 December 2018. A discussion of the major improvements as well as inconsistencies within the data is given. The former include a decrease in the uncertainty of the dimensionless fine-structure constant and a nearly two orders of magnitude improvement of particle masses expressed in units of kg due to the transition to the revised International System of Units (SI) with an exact value for the Planck constant. Further, because the elementary charge, Boltzmann constant, and Avogadro constant also have exact values in the revised SI, many other constants are either exact or have significantly reduced uncertainties. Inconsistencies remain for the gravitational constant and the muon magnetic-moment anomaly. The proton charge radius puzzle has been partially resolved by improved measurements of hydrogen energy levels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9888147PMC
http://dx.doi.org/10.1063/5.0064853DOI Listing

Publication Analysis

Top Keywords

recommended values
8
values
5
constant
5
codata recommended
4
values fundamental
4
fundamental physical
4
physical constants
4
constants 2018
4
2018 report
4
report 2018
4

Similar Publications

The neutrophil-to-lymphocyte ratio (NLR) may predict outcomes in end-stage liver disease, but its value after transjugular intrahepatic portosystemic shunt (TIPS) is unclear. This study explored the link between NLR and long-term outcomes in decompensated cirrhosis patients post-TIPS. We retrospectively analyzed 184 patients treated between January 2016 and December 2021, noting demographic data, lab results, and follow-up outcomes, including liver transplantation or death.

View Article and Find Full Text PDF

The preservation of the original configurations of root canals during endodontic preparation is crucial for treatment success. Nickel-titanium (NiTi) rotary systems have been refined to optimize canal shaping while minimizing iatrogenic errors. This study aimed to evaluate and compare the shaping efficacy of the novel R-Motion (RM) and the established WaveOne Gold (WG) systems using micro-computed tomography (micro-CT).

View Article and Find Full Text PDF

Net energy of grains for dairy goats differed with processing methods and grain types.

J Anim Sci Biotechnol

January 2025

College of Animal Science and Technology, Northwest A&F University, Yangling, Shaanxi, 712100, China.

Background: The diverse types and processing methods of grains intricately influence the sites and digestibility of starch digestion, thereby impacting energy utilization. This study aimed to explore the impact of grain variety and processing methods on the net energy (NE) in dairy goats, analyzing these effects at the level of nutrient digestion and metabolism.

Methods: Eighteen castrated Guanzhong dairy goats (44.

View Article and Find Full Text PDF

Background: Left ventricular (LV) myocardial contraction patterns can be assessed using LV mechanical dispersion (LVMD), a parameter closely associated with electrical activation patterns. Despite its potential clinical significance, limited research has been conducted on LVMD following myocardial infarction (MI). This study aims to evaluate the predictive value of cardiac magnetic resonance (CMR)-derived LVMD for adverse clinical outcomes and to explore its correlation with myocardial scar heterogeneity.

View Article and Find Full Text PDF

Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study.

Br J Anaesth

January 2025

Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria; Department of Anesthesiology and Intensive Care Medicine AUVA Trauma Center Salzburg, Academic Teaching Hospital of the Paracelsus Medical University, Salzburg, Austria.

Background: Bleeding guidelines currently recommend use of viscoelastic testing (VET) to direct haemostatic resuscitation in severe haemorrhage. However, VET-derived parameters of clot initiation, such as clotting time (CT) and activated clotting time (ACT), might not adequately reflect a clinically relevant interaction of procoagulant and anticoagulant activity, as revealed by thrombin generation assays. The aim of this study was to evaluate the ability of CT and ACT to indicate thrombin generation activity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!