Measurement of cervical softness before cerclage placement with an aspiration-based device.

Am J Obstet Gynecol MFM

Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Tufts Medical Center, Boston, MA. Electronic address:

Published: April 2023

Background: An abnormally soft cervix could contribute to the pathophysiology of cervical shortening and cervical insufficiency. Multiple techniques to measure cervical softness have been developed but none are used routinely in clinical practice. A clinically acceptable technique to measure cervical softness could improve identification of patients at risk for cervix-related preterm birth.

Objective: This study aimed to measure cervical softness in patients with cervical insufficiency and in normal controls using a novel, aspiration-based device. We hypothesized that the cervix is softer in patients with cervical insufficiency.

Study Design: This was a cross-sectional study of patients presenting for cerclage at a single academic medical center. Cervical softness was measured using a noninvasive, aspiration-based device placed on the anterior lip of the cervix during a speculum examination. The device measured the aspiration pressure required to displace cervical tissue to a predefined deformation level. Stiff tissue required increased aspiration pressure, whereas soft tissue required lower pressure values. Cerclage patients were subdivided into 3 groups, namely history-indicated, ultrasound-indicated, and examination-indicated cerclage. Controls were healthy volunteers between 12+0 weeks and 23+6 weeks of gestation without a history of cervical insufficiency and were matched by gestational age to the patients in the cerclage groups. Women with a cerclage in place, multiple gestations, active genital infection, or previous cervical excision procedures were excluded. Delivery information was subsequently recorded as well.

Results: Data from 133 women were analyzed; of those, 54 patients were in the cerclage group (23 history-indicated, 12 ultrasound-indicated, and 19 examination-indicated participants) and 79 were controls (40 in the first trimester and 39 in the second trimester groups). Patients who presented for ultrasound-indicated cerclage had significantly softer cervices (median; interquartile range) than second trimester controls (62 mbar; 50.5-114 vs 81 mbar; 75-101; P=.042). The difference in cervical softness was not significantly different between the history-indicated and examination-indicated cerclage groups and their respective control groups.

Conclusion: Patients presenting for ultrasound-indicated cerclage had significantly softer cervices than normal controls as measured by an aspiration-based device. Quantitative measurement of cervical softness with the aspiration-based device is a promising technique for objective measurement of cervical softness during pregnancy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajogmf.2023.100881DOI Listing

Publication Analysis

Top Keywords

cervical softness
32
aspiration-based device
20
cervical
14
measurement cervical
12
cervical insufficiency
12
measure cervical
12
cerclage
10
patients
9
softness
8
patients cervical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!