Organoids, the 3D culture systems derived from stem cells, are promising models for human organs. However, organoid study requires large-volume imaging with single cell resolution, which is beyond the spatial bandwidth limit of conventional optical microscopy. Herein, we propose a lensless holographic microscope empowered with a time and memory-saving algorithm. It solves the trade-off between the imaging field of view, resolution, and processing speed, and provides a practical tool for the study of organoids. We first build a compact microscopy system using a multi-angle LED illumination scheme and an on-chip structure. Then we develop a fast angular spectrum formula for fast reconstruction of oblique-illuminated coaxial holography under the under-sampling condition. Additionally, we derive a multi-angle illuminated filtered backpropagation algorithm to achieve high-precision and slice-wise recovery of 3D structures of objects. The reconstruction process demands only 1/50 of the memory required by a traditional optical diffraction tomography algorithm. Experimental results indicate that the proposed method can achieve 6.28 mm × 4.71 mm × 0.37 mm volume imaging within 104 s. Through the standardized polystyrene beads test, we demonstrate that the proposed microscope has micrometer-scale resolution in both lateral and axial directions. In addition, the 3D imaging results of salivary gland organoids show great application prospects of the proposed method in the field of living biological sampling imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.481627DOI Listing

Publication Analysis

Top Keywords

lensless holographic
8
holographic microscope
8
time memory-saving
8
memory-saving algorithm
8
large-volume imaging
8
proposed method
8
imaging
6
microscope time
4
algorithm
4
algorithm large-volume
4

Similar Publications

This work presents a method for simulating digital lensless holographic microscopy (DLHM) holograms using a physics-based image processing approach. While DLHM has gained significant attention in biology, biomedicine, and environmental monitoring, the current modeling of DLHM holograms has been limited, hindering potential applications, including learning-based solutions and generative model training. In this study, the DLHM propagation process is decomposed into the diffraction of a complex-valued spherical wavefront and the non-homogeneous magnification of the diffracted field that encodes the sample information, which accelerates and enhances the hologram simulation.

View Article and Find Full Text PDF

A fair comparison of multiple live cell cultures requires examining them under identical environmental conditions, which can only be done accurately if all cells are prepared simultaneously and studied at the same time and place. This contribution introduces a multiplexed lensless digital holographic microscopy system (MLS), enabling synchronous, label-free, quantitative observation of multiple live cell cultures with single-cell precision. The innovation of this setup lies in its ability to robustly compare the behaviour, i.

View Article and Find Full Text PDF

A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users.

View Article and Find Full Text PDF

Lensless microscopy is an imaging technique that allows high-resolution imaging over a large field of view with a cost-effective design. Conventional lensless microscopy often utilizes multi-height phase retrieval and pixel-super-resolution algorithms to reconstruct high-resolution images, requiring mechanical stages for three-dimensional relative movements between a light source, camera, and sample. However, the excessive use of stages inevitably increases the bulkiness of the system and extends the image acquisition time.

View Article and Find Full Text PDF

Optimization-based phase retrieval method for digital lensless holographic microscopy in the double-plane recording configuration is proposed. In our method the phase retrieval is framed as an optimization problem that can be efficiently and rigorously tackled with gradient decent tools. This is done with the conjugate gradient method that possesses excellent theoretical features such as global and fast convergence (compared to steepest descent) and relatively low computational cost (compared to second order optimizers).

View Article and Find Full Text PDF