Dose estimation by electron paramagnetic resonance (EPR) has been accomplished using the standard EPR dosimetry technique (ISO protocol 13304-1 for EPR retrospective dosimetry). However, different studies showed that these techniques have high measurement errors in measuring the low doses (10-100 mGy) in enamel. This work proposes a new method to make a dosimetric signal visible and measurable at low doses. The sample was purified using both chemical and mechanical processes. The pure sample mass and position and the EPR acquisition parameters were optimized to enhance the spectrometer's sensitivity for the quantitative low dose measurements. At the same time to reduce errors from the sample and spectrum anisotropy, the total doses (low plus spike) and the spike dose (4 Gy) were measured by rotating 0 to 360 degrees (i.e., 40 degrees at a time) relative to constant magnetic field direction using a goniometer. Subsequently, the spectra were averaged after their g-factor normalization. However, at low doses (<30 mGy), the radiation induced signal (RIS) was obscured by the background signal (BGS). So, the dose spiking technique was used as an alternative method. Ten low-dose deciduous molar tooth enamel (10-100 mGy) samples were spiked to the higher doses by delivering 4 Gy and measured using the X-band continuous wave (CW) EPR (Bruker EMXmicro) spectrometer. The total dose EPR signal was distinctly visible, and the peak-to-peak (P2P) amplitude height was measured. Then, the total dose was subtracted with the spike, often called a reference sample, to determine the initial low doses. The measurement errors using this method were lower than the previous methods. These results demonstrated that this method could be promising for solving low dose measurement problems in EPR dosimetry with deciduous and permanent tooth enamel.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/HP.0000000000001657 | DOI Listing |
Biophys Rev (Melville)
March 2025
School of Physics, Australian Centre for Microscopy and Microanalysis, Sydney Nano Institute, The University of Sydney, Sydney, NSW 2006, Australia.
The accurate detection of x-rays enables broad applications in various fields, including medical radiography, safety and security screening, and nondestructive inspection. Medical imaging procedures require the x-ray detection devices operating with low doses and high efficiency to reduce radiation health risks, as well as expect the flexible or wearable ones that offer more comfortable and accurate diagnosis experiences. Recently, halide perovskites have shown promising potential in high-performance, cost-effective x-ray detection owing to their attractive features, such as strong x-ray absorption, high-mobility-lifetime product, tunable bandgap, fast response, as well as low-cost raw materials, facile processing, and excellent flexibility.
View Article and Find Full Text PDFAesthet Surg J Open Forum
December 2024
Hyaluronic acid fillers rarely cause potentially devastating occlusive adverse events that require immediate hyaluronidase salvage infiltrations. An exploratory photographic investigation probed whether topical heparin's anticlotting and anti-inflammatory properties could synergize with and enhance the effectiveness of hyaluronidase. Based on heparin pharmacodynamics, the authors explored the rationale for associating topical heparins with hyaluronidase in treating occlusive side effects following accidental intra-arterial hyaluronic acid injections.
View Article and Find Full Text PDFAnim Reprod
January 2025
Hebei Key Laboratory of Animal Diversity, College of Life Sciences, Langfang Normal University, Hebei Langfang, China.
More than 90% of spermatozoa of boars in pork producing countries is stored in liquid at 17 °C; however, the quality of these spermatozoa is affected by bacterial breeding and oxidative damage. This study analyzed sperm quality and sperm capacitation after storage to study the effects of the effects of ZnO nanoparticles (ZnO NPs) supplementation on seminal plasma (SP)-free sperm preservation. We investigated the effects of adding 20, 50, 100 and 200 μg/mL of ZnO NPs to a seminal free boar sperm diluent over a 7-day period at 17 °C to assess the changes in non-capacitated/capacitated sperm quality parameters, antioxidant capacity, ATP content and extent of protein tyrosine phosphorylation.
View Article and Find Full Text PDFRev Cardiovasc Med
January 2025
Department of Cardiovascular Medicine, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, 100730 Beijing, China.
Background: Hypertension is one of the most prevalent disorders encountered in medical practice, yet effective pharmacotherapy options for resistant hypertension are limited. In this meta-analysis, we aimed to evaluate the efficacy and safety of aprocitentan in treating hypertension.
Methods: We searched PubMed, Embase, ClinicalTrials.
Cureus
December 2024
Gastroenterology, St Mark's Hospital and Academic Institute, London, GBR.
The therapeutic failure of infliximab therapy remains a challenge in patients with inflammatory bowel disease (IBD), and dose optimization is often required. Accelerated or intensified regimes showed value in treating patients in the acute setting with high CRP or low albumin levels, which are suggested by recent guidelines; however, evidence is weak. Therapeutic drug monitoring (TDM), with anti-tumor necrosis factor-alpha (TNF-α) trough levels and antibodies, showed value during maintenance therapy, but not in induction and can guide clinical decisions in patients that might be undertreated with the standard dosing regimen.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!