Background: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials.

Methods: Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05).

Results: The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05).

Conclusions: FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885647PMC
http://dx.doi.org/10.1186/s12903-023-02771-zDOI Listing

Publication Analysis

Top Keywords

marginal fit
16
polyvinyl siloxane
16
monolithic zirconia
12
scannable conventional
8
siloxane impression
8
impression materials
8
three-unit monolithic
8
scannable polyvinyl
8
group impression
8
dmp greece
8

Similar Publications

Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.

Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.

View Article and Find Full Text PDF

Glioma-induced alterations in excitatory neurons are reversed by mTOR inhibition.

Neuron

January 2025

Department of Pathology and Cell Biology, Irving Cancer Research Center, Columbia University Irving Medical Center, New York, NY 10032, USA; Department of Neurological Surgery, Columbia University Irving Medical Center, New York, NY 10032, USA. Electronic address:

Gliomas are aggressive neoplasms that diffusely infiltrate the brain and cause neurological symptoms, including cognitive deficits and seizures. Increased mTOR signaling has been implicated in glioma-induced neuronal hyperexcitability, but the molecular and functional consequences have not been identified. Here, we show three types of changes in tumor-associated neurons: (1) downregulation of transcripts encoding excitatory and inhibitory postsynaptic proteins and dendritic spine development and upregulation of cytoskeletal transcripts via neuron-specific profiling of ribosome-bound mRNA, (2) marked decreases in dendritic spine density via light and electron microscopy, and (3) progressive functional alterations leading to neuronal hyperexcitability via in vivo calcium imaging.

View Article and Find Full Text PDF

Introduction: Long-term care (LTC) residents are frequently transferred to acute care hospitals. Transfer decisions should align with residents' wishes and goals. Decision to transfer to hospital, when not aligned with the resident's wishes, can result in transfers that are harmful to residents, leaving residents in a state of disability that could be considered worse than death.

View Article and Find Full Text PDF

Pollution caused by environmental problems has aggravated the problem of resource scarcity, and the destruction of the ecological environment by mankind has shown serious consequences. Countries around the world are actively launching various carbon emission reduction and energy transformation policies to face this predicament. This paper investigates the risk spillover effects of China's carbon trading market with China's energy market and the U.

View Article and Find Full Text PDF

Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study).

BMC Oral Health

January 2025

Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Background: Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the fit accuracy and fracture resistance of these materials restricts their wider application in clinical restorative practices.

Aim Of The Study: This in vitro study aims to compare the marginal and internal fit, assess the fracture resistance, and evaluate the failure modes of crowns fabricated from advanced and conventional lithium disilicate materials.