Continuous control of intraocular pressure (IOP) is crucial to preventing long-term damage to the optic nerve in glaucoma. Recently, a novel telemetric IOP sensor (EYEMATE-IO™, Implandata Ophthalmic Products GmbH, Hannover, Germany) has been developed that continuously records IOP. The patient can read the IOP measurements wirelessly using a hand-held reading device. We present the case of a 70-year-old patient with primary open-angle glaucoma who had been implanted with an EYEMATE-IO™ and recently underwent minimally invasive bleb-filtering surgery with the PreserFlo MicroShunt (Santen, Osaka, Japan). This case demonstrates both the benefits of continuous pressure measurement with EYEMATE-IO™ and the ability of the PreserFlo MicroShunt to significantly reduce IOP fluctuations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9875318PMC
http://dx.doi.org/10.1177/25158414221149927DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
12
intraocular pressure
8
iop
5
detailed intraocular
4
pressure
4
pressure curve
4
curve telemetric
4
telemetric tonometry
4
tonometry implanted
4
implanted pressure
4

Similar Publications

Xen 63 versus Preserflo MicroShunt implant in patients with primary open-angle glaucoma.

Sci Rep

January 2025

Department of Ophthalmology and ORL, Faculty of Medicine, Clinico San Carlos Hospital, Complutense University, Clinico San Carlos Hospital Health Research Institute (IdISSC), Calle del Prof Martín Lagos, s/n,, Madrid, 28040, Spain.

This study compared the efficacy safety profiles of the Xen 63 and Preserflo MicroShunt devices, both standalone, in patients with primary open-angle glaucoma (POAG). It is a retrospective and single-center study conducted on consecutive on patients with medically uncontrolled POAG who underwent either a standalone Xen 63 or a standalone Preserflo and had a 12-month follow-up visit. The primary outcome was the mean IOP at month-12.

View Article and Find Full Text PDF

Preserflo MicroShunt (PMS) implantation is a minimally invasive surgical procedure for treating glaucoma. Postoperative hypotony, a common complication of PMS implantation, can be prevented and treated with 10-0 nylon insertion. In this report, we present a case of postoperative hypotony following PMS implantation that was treated with intraluminal insertion of 9-0 nylon.

View Article and Find Full Text PDF

Purpose: To investigate the efficacy and safety of the Preserflo MicroShunt (PMS) in treating glaucoma secondary to different uveitic glaucoma (UG) types in a European population.

Methods: This study evaluated consecutive eyes with UG that received the PMS. The primary outcome measure was 12-month surgical success (≥20% IOP reduction, target IOP of 6-21 mmHg).

View Article and Find Full Text PDF

Glaucoma and cataract often coexist. Patients with both conditions who qualify for surgical treatment may undergo either a combined surgical procedure or sequential treatments such as cataract surgery followed by an antiglaucoma procedure. A combined procedure with phacoemulsification is related to an increased risk of fibrosis of the filtering bleb; however, it is a rational approach for patients with high intraocular pressure and clinically significant lens opacification.

View Article and Find Full Text PDF

A 74-year-old Japanese woman with a history of primary open-angle glaucoma (POAG) in both eyes underwent PreserFlo MicroShunt (PFM) (Osaka, Japan: Santen Pharmaceutical, Co., Ltd.) implantation two years prior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!