Pulse rate (PR) is one of the most important markers for assessing a person's health. With the increasing demand for long-term health monitoring, much attention is being paid to contactless PR estimation using imaging photoplethysmography (iPPG). This non-invasive technique is based on the analysis of subtle changes in skin color. Despite efforts to improve iPPG, the existing algorithms are vulnerable to less-constrained scenarios (i.e., head movements, facial expressions, and environmental conditions). In this article, we propose a novel end-to-end spatio-temporal network, namely X-iPPGNet, for instantaneous PR estimation directly from facial video recordings. Unlike most existing systems, our model learns the iPPG concept from scratch without incorporating any prior knowledge or going through the extraction of blood volume pulse signals. Inspired by the Xception network architecture, color channel decoupling is used to learn additional photoplethysmographic information and to effectively reduce the computational cost and memory requirements. Moreover, X-iPPGNet predicts the pulse rate from a short time window (2 s), which has advantages with high and sharply fluctuating pulse rates. The experimental results revealed high performance under all conditions including head motions, facial expressions, and skin tone. Our approach significantly outperforms all current state-of-the-art methods on three benchmark datasets: MMSE-HR (MAE = 4.10 ; RMSE = 5.32 ; r = 0.85), UBFC-rPPG (MAE = 4.99 ; RMSE = 6.26 ; r = 0.67), MAHNOB-HCI (MAE = 3.17 ; RMSE = 3.93 ; r = 0.88).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2023.106592DOI Listing

Publication Analysis

Top Keywords

pulse rate
12
facial expressions
8
pulse
5
x-ippgnet novel
4
novel stage
4
stage deep
4
deep learning
4
learning architecture
4
architecture based
4
based depthwise
4

Similar Publications

Background: Heart failure (HF) is associated with systemic inflammation and hypercatabolic syndrome, impacting body metabolism. The advanced lung cancer inflammation index (ALI) is a novel inflammatory and nutritional biomarker. We aimed to investigate the prognostic role of ALI in patients with HF.

View Article and Find Full Text PDF

Fetal cardiac function in pregnancy affected by congenital heart disease: protocol for a multicentre prospective cohort study.

BMC Pregnancy Childbirth

January 2025

Royal Hospital for Women and UNSW, School of Clinical Medicine, Level 0, Royal Hospital for Women, Barker Street (Locked Bag 2000), Sydney, NSW, 2031, Australia.

Background: Congenital heart disease (CHD) is the most common fetal malformation, and it can result first in cardiac remodeling and dysfunction and later in cardiac failure and hydrops. A limited number of studies have evaluated cardiac function in fetuses affected by CHD. Functional parameters could potentially identify fetuses at risk of cardiac failure before its development.

View Article and Find Full Text PDF

To determine muscle oxygenation with continuous blood flow restriction (BFR) training in high load (HL), 80% one-repetition maximum (1RM) and low load (LL), 30% 1RM squat exercises. In week-2 of a 4-week resistance training programme as part of their 3-set training routine, two groups of athletes ( = 4 each), one performing HL training with low cuff pressure (20% arterial occlusion pressure (AOP)), the other LL training with high cuff pressure (60% AOP) had muscle oxygenation assessed with near-infrared spectrophotometry (NIRS), arterial oxygen saturation (SPO), heart rate (HR), barbell velocity and ratings of perceived exertion (RPE) during barbell back squats (BBS). Changes in the vastus lateralis oximetry were compared to pre- and post-training squat (1RM).

View Article and Find Full Text PDF

Predictors of Mortality in Venoarterial Extracorporeal Membrane Oxygenation Regardless of Early Left Ventricular Unloading: A National Experience.

J Cardiothorac Vasc Anesth

January 2025

Department of Anesthesia, Cardiothoracic Surgery/Cardiac ICU Section, Heart Hospital, Hamad Medical Corporation, Doha, Qatar; Department of Critical Care Medicine, Beni Suef University, Egypt; Weill Cornell Medical College, Doha, Qatar.

Objective: The use of an intra-aortic balloon pump (IABP) has been suggested to unload the left ventricle while on venoarterial extracorporeal membrane oxygenation (VA-ECMO) for cardiogenic shock (CS), leading to possibly improved in-hospital mortality. However, the predictors of mortality on dual mechanical circulatory support have not yet been evaluated, especially in real-world clinical settings. Therefore, a case-control study was conducted to determine the rate of all-cause mortality associated with VA-ECMO use regardless of left ventricular (LV) unloading, and with early LV unloading in the setting of CS, and to identify the predictors of mortality associated with VA-ECMO, with concurrent early LV unloading.

View Article and Find Full Text PDF

Background: Short-term improvements in quality of life (QOL) have been reported in adult congenital heart disease patients with systemic right ventricle (sRV) failure after treatment with sacubitril/valsartan. This study aimed to evaluate the medium-term QOL changes in sRV failure patients treated with sacubitril/valsartan.

Methods: In this single-centre, prospective cohort study, patients with symptomatic sRV failure completed the Netherlands Organisation for Applied Scientific Research/Academic Hospital Leiden Questionnaire for Adult's Health-Related Quality of Life (TAAQOL) at baseline and after starting treatment with sacubitril/valsartan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!