Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: To establish the pharmacokinetic (PK) and pharmacodynamic (PD) equivalence of proposed biosimilar Insulin N (Biocon's Insulin-N; Biocon Biologics Ltd., Bangalore, India) and US-licensed Humulin® N (Humulin-N; Eli Lilly and Company, Indianapolis, IN, USA) in healthy subjects.
Materials And Methods: This was a phase-1, single-centre, double-blind, randomized, three-period, six-sequence, partially replicated, crossover, 24-h euglycaemic clamp study. Overall, 90 healthy subjects were randomized, of whom 85 completed the study. The subjects received either two single doses of Biocon's Insulin-N and a single dose of Humulin-N or two single doses of Humulin-N and a single dose of Biocon's Insulin-N subcutaneously at a dose of 0.4 IU/kg. The primary PK endpoints were the area under the insulin concentration-time curve from 0 to 24 h (AUC ) and the maximum insulin concentration (C ). The primary PD endpoints were the area under the glucose infusion rate (GIR) curve from 0 to 24 h (AUC ) and the maximum GIR (GIR ).
Results: Biocon's Insulin-N was found to be equivalent to Humulin-N for the primary PK (geometric 90% confidence interval for the least squares mean ratio: AUC , 100.98%-115.66% and C , 95.91%-110.16%) and PD endpoints (intra-subject variability ≥0.294; 95% upper confidence interval [(μT - μR) - θσ WR] <0; point estimates of geometric least squares mean ratio: AUC , 104.61% and GIR , 100.81%). The safety profile of Biocon's Insulin-N was similar to that of Humulin-N, and no serious adverse events were reported.
Conclusion: PK and PD equivalence was shown between Biocon's Insulin-N and Humulin-N in healthy subjects, and both treatments were well tolerated and considered safe.