Objective: To compare marginal changes at bone-level implants restored with screw-retained implant prosthesis with or without intermediate standardised abutments, after 1 year of follow-up.

Materials And Methods: Thirty-six partially edentulous patients received 72 implants. Each patient received 2 implants and a 2- to 4-unit screw-retained implant-prosthesis. The test group received implants consisting of a screw-retained prosthesis connected directly to the implant shoulder, while the prostheses in the control group were connected through a 3-mm standardised intermediate abutment. Clinical and radiological data were recorded at baseline and at 3, 6 and 12 months in follow-up visits.

Results: At 12 months, the marginal bone loss was 0.17 ± 0.24 mm for the test group (19 patients) and 0.09 ± 0.15 mm for the control group (17 patients), with no statistically significant differences (p > .05). The mean probing pocket depth was 2.96 mm ± 0.46 for the test group and 2.86 ± 0.62 mm for the control group. The test and control groups showed bleeding on probing levels of 18.86 ± 14.12% and 13.73 ± 17.66%, respectively. All patients scored below 25% on the plaque index levels.

Conclusions: Restoration of bone-level implants with fixed screw-retained partial prostheses with or without intermediate abutments presented similar radiographic and clinical outcomes after 1 year.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.14039DOI Listing

Publication Analysis

Top Keywords

bone-level implants
12
received implants
12
test group
12
control group
12
marginal changes
8
changes bone-level
8
fixed screw-retained
8
screw-retained partial
8
prostheses intermediate
8
intermediate standardised
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!