A vascularized composite tissue allotransplantation (VCA) was performed at the Children's Hospital of Philadelphia (CHOP), on an 8-year-old patient in 2015, six years after bilateral hand and foot amputation. Hand VCA resulted in reafferentation of the medial, ulnar, and radial nerves serving hand somatosensation and motor function. We used magnetoencephalography (MEG) to assess somatosensory cortical plasticity following the post-transplantation recovery of the peripheral sensory nerves of the hands. Our 2-year postoperative MEG showed that somatosensory lip representations, initially observed at "hand areas", reverted to canonical, orthotopic lip locations with recovery of post-transplant hand function. Here, we continue the assessment of motor and somatosensory responses up to 6-years post-transplant. Magnetoencephalographic somatosensory responses were recorded eight times over a six-year period following hand transplantation, using a 275-channel MEG system. Somatosensory tactile stimuli were presented to the right lower lip (all 8 visits) as well as right and left index fingers (visits 3-8) and fifth digits (visits 4-8). In addition, left and right-hand motor responses were also recorded for left index finger and right thumb (visit 8 only).During the acute recovery phase (visits 3 and 4), somatosensory responses of the digits were observed to be significantly larger and more phasic (i.e., smoother) than controls. Subsequent measures showed that digit responses maintain this atypical response profile (evoked-response magnitudes typically exceed 1 picoTesla). Orthotopic somatosensory localization of the lip, D2, and D5 was preserved. Motor beta-band desynchrony was age-typical in localization and response magnitude; however, the motor gamma-band response was significantly larger than that observed in a reference population.These novel findings show that the restoration of somatosensory input of the hands resulted in persistent and atypically large cortical responses to digit stimulation, which remain atypically large at 6 years post-transplant; there is no known perceptual correlate, and no reports of phantom pain. Normal somatosensory organization of the lip, D2, and D5 representation remain stable following post-recovery reorganization of the lip's somatosensory response.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brainres.2023.148262 | DOI Listing |
Br J Anaesth
January 2025
Department of Anesthesiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China. Electronic address:
Background: Chronic neuropathic pain generally has a poor response to treatment with conventional drugs. Sympathectomy can alleviate neuropathic pain in some patients, suggesting that abnormal sympathetic-somatosensory signaling interactions might underlie some forms of neuropathic pain. The molecular mechanisms underlying sympathetic-somatosensory interactions in neuropathic pain remain obscure.
View Article and Find Full Text PDFPLoS Biol
January 2025
Department of Neurology, School of Medicine and Health, Technical University of Munich (TUM), Munich, Germany.
Pain is closely linked to alpha oscillations (8 < 13 Hz) which are thought to represent a supra-modal, top-down mediated gating mechanism that shapes sensory processing. Consequently, alpha oscillations might also shape the cerebral processing of nociceptive input and eventually the perception of pain. To test this mechanistic hypothesis, we designed a sham-controlled and double-blind electroencephalography (EEG)-based neurofeedback study.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:
Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.
View Article and Find Full Text PDFJ Neurophysiol
January 2025
Dept of Neuroscience and Regenerative Medicine, Medical College of Georgia, Augusta University, Augusta, GA, USA.
Deep brain stimulation (DBS) using electrical stimulation of neuronal tissue in the basal forebrain to enhance release of the neurotransmitter acetylcholine is under consideration to improve executive function in patients with dementia. While some small studies indicate a positive response in the clinical setting, the relationship between DBS and acetylcholine pharmacokinetics is incompletely understood. We examined the cortical acetylcholine response to different stimulation parameters of the basal forebrain.
View Article and Find Full Text PDFNeuropsychologia
January 2025
Queensland Brain Institute, The University of Queensland, Australia; School of Psychology, The University of Queensland, Australia; CIFAR, Canada.
Endogenous visuo-spatial attention is under the control of a fronto-parietal network of brain regions. One key node in this network, the intra-parietal sulcus (IPS), plays a crucial role in maintaining endogenous attention, but little is known about its ongoing physiology and network dynamics during different attentional states. Here, we investigated the reactivity of the left IPS in response to brain stimulation under different states of selective attention.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!