Introduction: The objective of this study was to compare the mechanical and structural properties of the nickel-titanium (Ni-Ti) alloy already used in endodontics with titanium-molybdenum (Ti-Mo) and titanium-niobium (Ti-Nb) alloys to determine if these can be suggested in the manufacture of endodontic files.
Methods And Materials: Orthodontic wires made of the different alloys were used. The previously mentioned alloys were characterized by energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and torsion tests. Cyclic fatigue tests were performed on a simulated canal with a curvature of 86° to 375 rpm. The fractured surfaces of the wires were observed by means of scanning electron microscopy (SEM). A Kruskal-Wallis test and U Mann Whitney test were used to determine significant differences in cyclic fatigue between groups.
Results: In the mechanical tests, similar values of torsion were found for the three alloys. In XRD, the Ti-Nb showed less structural changes. In the cyclic fatigue test, Ti-Nb was found to be significantly more resistant with respect to Ni-Ti and Ti-Mo.
Conclusion: Based on our study, Ti-Nb is suggested as a possible alloy for the manufacture of rotary files due to its impressive properties.