In recent years, complete denture construction has been revolutionized using computer-aided designing and computer-aided manufacturing (CAD-CAM) technology. This clinical study compared the retention and denture base adaptation of 3D-printed complete dentures fabricated using dimethacrylate-based resins with a photoinitiator versus conventional complete dentures. Ten completely edentulous patients were nominated for this study. Each patient received two complete dentures. One complete denture was conventionally fabricated, while the other was digitally fabricated through 3D printing of dimethacrylate-based resins with a photoinitiator. Denture base adaptation for both dentures was evaluated using surface matching software. Denture retention was also evaluated using a digital force meter at the time of complete denture insertion (T ), after three months (T ) and six months (T ) of denture use. Regarding adaptation (mean misfit values), a statistically insignificant difference was detected between the two differently fabricated complete dentures. In addition, comparable satisfactory retention values were observed for both conventionally fabricated and 3D-printed dentures; however, there was an insignificant increase in retention over time. 3D-printed complete dentures fabricated using dimethacrylate-based resins could be a promising alternative to conventionally fabricated complete dentures with satisfactory denture base adaptation and retention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9871175PMC
http://dx.doi.org/10.34172/joddd.2022.030DOI Listing

Publication Analysis

Top Keywords

complete dentures
28
denture base
16
base adaptation
16
3d-printed complete
12
complete denture
12
dimethacrylate-based resins
12
conventionally fabricated
12
complete
10
denture
9
dentures
9

Similar Publications

Aim: The aim of the present study was to comparatively evaluate the retention of complete dentures and oral health-related quality of life (OHRQoL) of patients with conventional and bioelectric impressions or transcutaneous electric nerve stimulation (TENS).

Materials And Methods: A total of thirty (n = 30) completely edentulous patients were randomly distributed into two groups: Group-C (n = 15) (Conventional) and Group-T (n = 15) (bioelectric). In Group C, border molding was performed using the manual manipulation of borders, and the final impression was made using zinc-oxide eugenol.

View Article and Find Full Text PDF

In vitro analysis of composition profiles of resins for 3D printing of dentures.

J Dent

January 2025

Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland. Electronic address:

Objective: This study aimed to investigate the resin compounds from CAD-CAM 3D-printed denture resins, focusing on the identification and classification of free monomers and other components. The primary objective was to determine the chemical profile of these 3D-prinding resin materials.

Methods: Four 3D-printed denture resins, two base materials (1: DentaBASE, Asiga Ltd.

View Article and Find Full Text PDF

Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

J Dent

January 2025

Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland; School of Dentistry, Federal University of Goiàs, Goiania, Brazil; Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Objective: This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients.

Methods: Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at central occlusion (OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP.

View Article and Find Full Text PDF

Prevalence and type of removable prostheses manufactured in dental laboratories in Switzerland over the last 10 years.

Swiss Dent J

January 2025

Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.

Due to effective preventive measures and advanced techniques in operative dentistry, tooth loss occurs later in life and implant restorations have become a common solution for replacement of missing teeth. Therefore, the use of removable dental prostheses (RDPs) is expected to decline over time. This study aims to evaluate the expected decrease in the production of RDPs in Swiss dental laboratories over the past decade.

View Article and Find Full Text PDF

Wooden Plate Denture Reproduced Using Materials and Methods From 400 Years Ago.

Cureus

December 2024

Department of Oral and Maxillofacial Surgery, National Hospital Organization, Kyoto Medical Center, Kyoto, JPN.

This study aimed to reproduce a complete wooden plate denture, which was the first in the world to retain suction under negative pressure, using the same materials and methods from 400 years ago (i.e., the Edo period) to verify its masticatory performance.

View Article and Find Full Text PDF