A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioimpedance-based Authentication of Defrosted Versus Fresh Pork at the End of Refrigerated Shelf Life. | LitMetric

Correct food labeling is a legal requirement and helps consumers to make informed purchasing choices. Mislabeling defrosted meat as fresh is illegal in the EU. However, there are no standardized technologies to authenticate fresh versus defrosted meat. We address this by testing if bioimpedance-based measurements can separate defrosted meat from refrigerated-only meat at the end of shelf life, i.e., when also fresh meat shows deterioration. Pork sirloin samples from 20 pigs were first tested at 12 days postmortem ('fresh group'). This time point was chosen to represent a typical use-by date for refrigerated storage of fresh pork. Then, all samples were transferred to a -24°C freezer for 3 days and thawed for 2 days before final testing ('frozen-thawed group'). Bioimpedance analyses (BIA) were done in a frequency range of [10-10 Hz]. Weight, pH and electrode positioning were assessed to test for potential confounding effects. Statistics for treatment dependent differences were based on the established P parameter and phase angle, which were extracted from the BI spectra. We found that using bioimpedance testing with tetrapolar electrodes, P and phase angle allowed almost complete separation of fresh and previously frozen samples. However, within the whole sample population, there was some overlap between the spectra of fresh and frozen samples. Yet, based on P, only one fresh sample (5% of N=20) fell in the lowest P class with all the frozen samples. We used a multifactorial design that allowed to test the effects of potential confounding factors, such as electrode positioning and meat quality parameters. We found a relatively low explained variance for the P parameter, indicating that confounding effects from other factors or quality defects in fresh pork may affect the detection capacity of bioimpedance-based authentication of fresh pork. Our data, therefore, suggest that reliable fresh-label authentication with bioimpedance testing should be based on testing a small number of samples to represent a specific lot of pork that is to be inspected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837875PMC
http://dx.doi.org/10.2478/joeb-2022-0017DOI Listing

Publication Analysis

Top Keywords

fresh pork
16
defrosted meat
12
frozen samples
12
fresh
10
bioimpedance-based authentication
8
shelf life
8
electrode positioning
8
potential confounding
8
confounding effects
8
phase angle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!