Background And Aim: Pulse field ablation (PFA) has emerged as a safe alternative to other catheter ablation energy sources for patients. Although early results are encouraging, secondary data about outcomes are lacking. Herein, we aimed to assess the safety and efficacy of the novel technique.

Methods: We searched PubMed, Ovid, Google Scholar, Web of Science, and Scopus databases and several major scientific conferences for studies reporting results regarding PFA.

Results: Sixteen studies were included, reporting 485 patients with atrial fibrillation who underwent pulsed field operations. Patients averaged 60 years of age. The total duration of the procedure is 94 min. The average Fluoro procedure takes 17 min. Isolation of all pulmonary veins was 100% with a 95% confidence interval (CI) ( > 0.05). Overall, the recurrence rate of arrhythmia in the participants was 2.84% (95% CI) ( > 0.05). Complications were detected during or after the PFA procedure at a rate of 2.23% ( < 0.05), with 95% CI indicating the high safety of the PFA procedure.

Conclusion: Using pulsed-field ablation as a new treatment for atrial fibrillation has proven safe and effective.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852677PMC
http://dx.doi.org/10.1002/hsr2.1079DOI Listing

Publication Analysis

Top Keywords

pulsed field
8
field ablation
8
ablation pfa
8
atrial fibrillation
8
efficacy safety
4
safety novel
4
novel pulsed
4
pfa technique
4
technique atrial
4
fibrillation systematic
4

Similar Publications

Background: Luminal and hemodynamic evaluations of the cervical arteries inform the diagnosis and management of patients with cervical arterial disease.

Purpose: To demonstrate a 3D nonenhanced quantitative quiescent interval slice-selective (qQISS) magnetic resonance angiographic (MRA) strategy that provides simultaneous hemodynamic and luminal evaluation of the cervical arteries.

Study Type: Prospective.

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Purpose: Pulsed electrical field (PEF) ablation is an energy-based technique used to treat a range of cancers by irreversible electroporation (IRE). Our objective was to use computational and plant-based models to characterize the electric field distribution and ablation zones induced with a commercial 8-needle array-based applicator intended for treatment of skin cancer when high-frequency IRE (H-FIRE) pulses are applied. Electric field characterisation of this device was not previously assessed.

View Article and Find Full Text PDF

Photonic crystals (PC) play a key role in optical field modulation due to their unique photonic band gaps (PBGs). Anodic aluminum oxide (AAO) prepared by pulse anodization is a promising candidate for PC devices. In this research, an AAO-based PC with multi-band was fabricated on a single-slice & single-material film, which exhibits multi-band responses in the visible-to-near-infrared (vis-NIR) region.

View Article and Find Full Text PDF

Proteases, an important class of enzymes that cleave proteins and peptides, carry a wealth of potentially useful information. Devices to enable routine and cost effective measurement of their activity could find frequent use in clinical settings for medical diagnostics, as well as some industrial contexts such as detecting on-line biological contamination. In particular, devices that make use of readouts involving magnetic particles may offer distinct advantages for continuous sensing because material they release can be magnetically captured downstream and their readout is insensitive to optical properties of the sample.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!