Objective: By constructing the three-dimensional finite element model of two-level OLIF lumbar spine, the aim of this study was to demonstrate the feasibility and effectiveness of posterior four-screw fixation for treatment of two-level lumbar degenerative diseases from the perspective of biomechanics.
Methods: An intact L3-S1 segment nonlinear lumbar finite element model (M0) was constructed from the CT scanning data of a healthy adult. After verification, two-level OLIF procedure were simulated, and three patterns of finite element analysis models were constructed: two-level stand-alone OLIF group (M1), two-level OLIF + four-screw fixation group (M2) and two-level OLIF + six-screw fixation group (M3). Range of motion, stress of the cage, and stress of fixation were evaluated in the different models.
Results: Under various motion modes,the ROM of M2 and M3 were significantly lower than those of M1. The ROM reduction of M2 relative to M1 was much greater than that of M3 relative to M2. Moreover, the peak von Mises stresses of endplates in M2 were almost the same as those in M3. In terms of the maximum stresses of cages, M2 and M3 were essentially identical. Besides, the maximum stresses of posterior instrumentation in M2 and M3 were similar, which were mainly concentrated at the root of pedicle screws.
Conclusion: There were no significant differences between M2 and M3 from the biomechanical analysis. In two-level OLIF, posterior four-screw fixation can replace six-screw fixation, which reduces surgical trauma and decreases economic burden of patients, and will be a cost-effective alternative.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clineuro.2023.107597 | DOI Listing |
Medicina (Kaunas)
December 2024
Division of Spine, Department of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore 308433, Singapore.
Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.
View Article and Find Full Text PDFZhongguo Yi Xue Ke Xue Yuan Xue Bao
June 2024
Department of Orthopedics, The First Affiliated Hospital of Ningbo University,Ningbo,Zhejiang 315010,China.
Objective To demonstrate the feasibility of oblique lumbar interbody fusion (OLIF) combined with 4-screw fixation for treating two-level lumbar degenerative diseases.Methods An intact finite element model of L3-S1 (M0) was constructed and validated.Then,we constructed the M1 model by simulating OLIF surgery at L3/4 and L4/5 segments on the M0 model.
View Article and Find Full Text PDFEur Spine J
May 2024
Department of Orthopedic Surgery, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, Republic of Korea.
Purpose: To identify the factors associated with a correction of the segmental angle (SA) with a total change greater than 10° in each level following minimally invasive oblique lumbar interbody fusion (MIS-OLIF).
Methods: Patients with lumbar spinal stenosis who underwent single- or two-level MIS-OLIF were reviewed. Segments with adequate correction of the SA >10° after MIS-OLIF in immediate postoperative radiograph were categorized as discontinuous segments (D segments), whereas those without such improvement were assigned as continuous segments (C segments).
Front Med (Lausanne)
June 2023
Department of Orthopaedic Surgery, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, China.
Objective: The aim of this study was to verify the biomechanical properties of a newly designed angulated lateral plate (mini-LP) suited for two-level oblique lumbar interbody fusion (OLIF). The mini-LP is placed through the lateral ante-psoas surgical corridor, which reduces the operative time and complications associated with prolonged anesthesia and placement in the prone position.
Methods: A three-dimensional nonlinear finite element (FE) model of an intact L1-L5 lumbar spine was constructed and validated.
Clin Neurol Neurosurg
February 2023
Department of Orthopaedics, Ningbo First Hospital, Ningbo, China. Electronic address:
Objective: By constructing the three-dimensional finite element model of two-level OLIF lumbar spine, the aim of this study was to demonstrate the feasibility and effectiveness of posterior four-screw fixation for treatment of two-level lumbar degenerative diseases from the perspective of biomechanics.
Methods: An intact L3-S1 segment nonlinear lumbar finite element model (M0) was constructed from the CT scanning data of a healthy adult. After verification, two-level OLIF procedure were simulated, and three patterns of finite element analysis models were constructed: two-level stand-alone OLIF group (M1), two-level OLIF + four-screw fixation group (M2) and two-level OLIF + six-screw fixation group (M3).