A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Rapid and Easy Method of MALDI Biotyper Antibiotic Susceptibility Test Rapid Assay To Provide Early Meropenem Susceptibility Profile in . | LitMetric

A Rapid and Easy Method of MALDI Biotyper Antibiotic Susceptibility Test Rapid Assay To Provide Early Meropenem Susceptibility Profile in .

Microbiol Spectr

Programa de Pós-Graduação em Ciências Farmacêuticas-Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.

Published: February 2023

Antimicrobial susceptibility testing (AST) that can provide faster results is necessary. The MALDI Biotyper antibiotic susceptibility test rapid assay (MBT-ASTRA) can provide early AST results but still needs to be simplified in order to facilitate its execution by microbiology laboratories. The aim of this study was to evaluate an adaptation of MBT-ASTRA. Isolates of were tested for meropenem susceptibility by MBT-ASTRA using a solution prepared from meropenem disks and performing a manual spectrum analysis. The relative growth (RG) was calculated for each isolate, and a cutoff value was established to determine the susceptibility profile of the isolates. Results of the adapted method were compared with the standard susceptibility method (broth microdilution). An adapted method of MBT-ASTRA was developed. The RG cutoff values for meropenem were ≤0.1510 for susceptibility and >0.6272 for resistance, presenting 95.65% categorical agreement, with 2.9% (2/69) minor discrepancy and 3.23% (1/31) very major discrepancy. MBT-ASTRA can be used to provide rapid AST results with a simpler and more accessible protocol, especially regarding spectrum analysis. The simplification of the MBT-ASTRA technique, especially in spectrum analysis, can considerably allow more laboratories to rapidly determine antimicrobial susceptibility profiles.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9927374PMC
http://dx.doi.org/10.1128/spectrum.04375-22DOI Listing

Publication Analysis

Top Keywords

spectrum analysis
12
susceptibility
9
maldi biotyper
8
biotyper antibiotic
8
antibiotic susceptibility
8
susceptibility test
8
test rapid
8
rapid assay
8
provide early
8
meropenem susceptibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!