Unlabelled: Faster resolution of hypoxaemic or hyperoxaemic events in preterm infants may reduce long-term neurodevelopmental impairment. Automatic titration of inspiratory oxygen increases time within the oxygen saturation target range and may provide a more prompt response to hypoxic and hyperoxic events. We assessed routinely performed follow-up at 2 years of age after the implementation of automated oxygen control (AOC) as standard care and compared this with a historical cohort. Neurodevelopmental outcomes at 2 years of age were compared for infants born at 24-29 weeks gestational age before (2012-2015) and after (2015-2018) the implementation of AOC as standard of care. The primary outcome was a composite outcome of either mortality or severe neurodevelopmental impairment (NDI), and other outcomes assessed were mild-moderate NDI, Bayley-III composite scores, cerebral palsy GMFCS, and CBCL problem behaviour scores. A total of 289 infants were included in the pre-AOC epoch and 292 in the post-AOC epoch. Baseline characteristics were not significantly different. Fifty-one infants were lost to follow-up (pre-AOC 6.9% (20/289), post-implementation 10.6% (31/292). The composite outcome of mortality or severe NDI was observed in 17.9% pre-AOC (41/229) vs. 24.0% (47/196) post-AOC (p = 0.12). No significant differences were found for the secondary outcomes such as mild-moderate NDI, Bayley-III composite scores, cerebral palsy GMFCS, and problem behaviour scores, with the exception of parent-reported readmissions until the moment of follow-up which was less frequent post-AOC than pre-AOC.
Conclusion: In this cohort study, the implementation of automated oxygen control in our NICU as standard of care for preterm infants led to no statistically significant difference in neurodevelopmental outcome at 2 years of age.
What Is Known: • Neurodevelopmental outcome is linked to hypoxemia, hyperoxaemia and choice of SpO2 target range. • Automated titration of inspired oxygen may provide a faster resolution of hypoxaemic and hyperoxaemic events.
What Is New: • This cohort study did not find a significant difference in neurodevelopmental outcome at two years of age after implementing automated oxygen control as standard of care.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10167103 | PMC |
http://dx.doi.org/10.1007/s00431-023-04809-4 | DOI Listing |
Molecules
December 2024
School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132012, China.
In this paper, the enhancement of thermochemical energy storage by alkali metal chloride salts-doped Ca-based sorbents is revealed by experiments and DFT calculations. The results indicate that NaCl and KCl doping increases the reaction rate and cycle stability. Compared to CaO, the conversion of NaCl-CaO and KCl-CaO after one cycle is increased by 59.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China.
Characterized by their high sensitivity and flexible deformation, flexible pressure sensors have been extensively applied in various fields such as wearable electronics, health monitoring, soft robotics, and human-computer interaction. In this research, we developed a dual-response pressure sensor (DRPS) designed to identify object materials. By integrating the operating principles of capacitive and resistive sensors and employing microstructured dielectric layers, we enhanced the sensitivity and detection range of the pressure sensor.
View Article and Find Full Text PDFLab Chip
January 2025
Nanobioelectronics Laboratory (NBEL), Department of Biomedical Engineering, Ilse Katz Institute for Nanoscale Science and Technology, Ben-Gurion University of the Negev, 8410501 Beer Sheva, Israel.
Dissolved oxygen is crucial for metabolism, growth, and other complex physiological and pathological processes; however, standard physiological models (such as organ-on-chip systems) often use ambient oxygen levels, which do not reflect the lower levels that are typically found . Additionally, the local generation of reactive oxygen species (ROS; a key factor in physiological systems) is often overlooked in biology-mimicking models. Here, we present a microfluidic system that integrates electrochemical dissolved oxygen sensors with lab-on-a-chip technology to monitor the physiological oxygen concentrations and generate hydrogen peroxide (HO; a specific ROS).
View Article and Find Full Text PDFJ Robot Surg
January 2025
Department of Pediatric Anesthesia and Intensive Care, Necker-Enfants Malades University Hospital, AP-HP Centre, Université Paris Cité, 149, Rue de Sèvres 75015, Paris, France.
Retroperitoneal robotic-assisted laparoscopic pyeloplasty (R-RALP) is the commonest urologic procedure performed in children, entailing retroperitoneal CO2 insufflation and lateral decubitus, whose effects on cardiopulmonary variables are poorly known. We, therefore, studied hemodynamic and respiratory changes due to CO2 insufflation and lateral decubitus in children undergoing R-RALP and their effects on regional tissue oxygenation. Between 1/2021 and 7/2024, children affected by ureteropelvic joint obstruction (UPJO) underwent a pyeloplasty by R-RALP at Necker Enfants Malades Hospital (Paris, France), using a standardized surgical technique and a lung-protecting anesthetic protocol aimed to prevent hypercarbia.
View Article and Find Full Text PDFEur J Pediatr
January 2025
Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, Denmark Hill, London, UK.
Unlabelled: Infants requiring interhospital transfer for a higher level of care in the neonatal period are at increased risk of adverse outcomes. Optimising respiratory management is an important priority. The aim of this survey was to investigate current respiratory support strategies in neonatal transport and identify opportunities for the optimisation of clinical care and future research.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!