Alloy 718 is commonly used in the maritime and aerospace industries due to its strength and durability, particularly in engine rotating components such as disks, fan blades, and high-pressure compressors. As a new type of 3D printing technology, directed energy deposition (DED) can employ lasers to melt metal powders or wires to fabricate arbitrary-shaped workpieces directly from customized data, thereby making machining more synergistic and intuitive. However, the surface properties of the DED-printed alloy 718 samples, such as surface roughness and wear resistance, are typically subpar. By introducing severe plastic deformation to the near-surface, ultrasonic nanocrystal surface modification (UNSM) can be used as a post-processing method and results in altered properties. The uniaxial tensile test reveals that the UNSM-treated alloy 718 exhibits a higher mechanical property. Moreover, using a fretting test rig in accordance with the cylinder-on-plane agreement, a higher wear resistance for UNSM-treated alloy 718 is observed. This study employs the finite element method to fully comprehend the effect of UNSM on wear performance. The fretting wear process of Inconel 718 alloy is established using an energy-based finite element model. Considering the severe practical scenarios, the Johnson-Cook constitutive model is implemented, with the linear isotropic hardening model capturing the plastic behavior. In comparison to experimental measurements, the finite element results demonstrate unprecedented wear loss consistency with an error of less than 2%. Therefore, we conclude that the finite element model built in this study exhibits a high accuracy and can be used to analyze the effect of UNSM on fretting wear behavior. According to finite element analysis, as the normal load increases, the improvement in wear resistance induced by UNSM decreases. Given that the finite element model is based on the energy method, the effects of coefficient of friction (COF) and wear coefficient modified by UNSM are investigated separately. According to the findings, the UNSM-modified COF and wear coefficient play a significant role in determining the wear characteristics. Due to the removal of a substantial amount of material from the central area of the alloy 718 surface by wear, it is also possible to observe that severe plastic strains are primarily concentrated at the edges of the wear scars.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9873943PMC
http://dx.doi.org/10.1038/s41598-023-28128-8DOI Listing

Publication Analysis

Top Keywords

finite element
24
alloy 718
20
fretting wear
12
wear
12
wear resistance
12
element model
12
wear behavior
8
inconel 718
8
718 alloy
8
severe plastic
8

Similar Publications

This article uses the engineering background of the Zhengzhou Metro Line 5 with a cement-soil group pile composite foundation. It simplifies the composite foundation using the area-weighted composite modulus method and establishes a finite element model of a double-line EPBM passing beneath the cement-soil group pile composite foundation building. The calculation results were compared and validated against monitoring data.

View Article and Find Full Text PDF

Parametric finite element modeling of reinforced polymeric leaflets for improved durability.

J Mech Behav Biomed Mater

January 2025

School of Materials Science and Engineering, Colorado State University, 700 Meridian Ave, Fort Collins, 80523, CO, USA. Electronic address:

Hyaluronic acid-enhanced polyethylene polymeric TAVR shows excellent in vivo anti-calcific, anti-thrombotic, and in vitro hydrodynamic performance. However, during durability testing, impact wear and fatigue cause early valve failure. Heart valve durability can be improved by strengthening the leaflet with fiber reinforcement.

View Article and Find Full Text PDF

Machine learning and statistical shape modelling for real-time prediction of stent deployment in realistic anatomies.

Comput Methods Programs Biomed

January 2025

Mines Saint-Etienne, Univ Jean Monnet, Etablissement Francais du Sang, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France. Electronic address:

The rise in minimally invasive procedures has created a demand for efficient and reliable planning software to predict intra- and post-operative outcomes. Surrogate modelling has shown promise, but challenges remain, particularly in cardiovascular applications, due to the complexity of parametrising anatomical structures and the need for large training datasets. This study aims to apply statistical shape modelling and machine learning for predicting stent deployment in real time using patient-specific models.

View Article and Find Full Text PDF

This study delves into the feasibility of leveraging quasi-static component (QSC) generation during primary Lamb wave propagation to discern subtle alterations in the interfacial properties of a two-layered plate. Unlike the second-harmonic generation of Lamb waves, QSC generation doesn't necessitate precise phase-velocity matching but rather requires an approximate matching of group velocities to ensure the emergence of cumulative growth effects. This unique characteristic empowers the QSC-based nonlinear ultrasonic method to effectively surmount the limitations associated with inherent dispersion and multimode traits of Lamb wave propagation.

View Article and Find Full Text PDF

Background: Low back pain affects over 80 % of adults, with sacroiliac joint dysfunction accounting for 15-30 % of these cases. Sacroiliac fusion is a surgical procedure for refractory joint pain. While the biomechanics of the joint and its fusion relative to the spinal column are well-known, the hip-spine relationship post-fusion remains unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!