A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visual Assay for Methicillin-Resistant Based on Rolling Circular Amplification Triggering G-Quadruplex/Hemin DNAzyme Proximity Assembly. | LitMetric

Nowadays, infections caused by methicillin-resistant (MRSA) have constituted a new challenge for anti-infective treatment. Precise identification and rapid clinical diagnostics of MRSA from other methicillin-sensitive strains entail assays with robust diagnostic efficiency and simple operation steps. Sensitive detection of MecA gene is promising to indicate MRSA infection, but it is challenged by the lack of isothermal and simple strategies. A visual assay based on isothermal rolling circular amplification and G-quadruplex/hemin (G4/hemin) DNAzyme proximity assembly was proposed for the immediate, efficient, and cost-effective detection of MecA in simple operation steps and in a single tube. The presence of MecA specifically drove the formation of circular templates, which further triggered isothermal amplification. The amplified product offered abundant binding sites for DNA-grafted hemin probes to form a novel proximity-assembled G4/hemin DNAzyme structure for colorimetric changing diagnosis. This tandem-repeated novel DNAzyme possessed higher catalytic activity and a lower background signal than traditional G4/hemin DNAzyme, ensuring sensitive discrimination of MRSA (limit of detection: 9.6 pM). Assay stability and antimatrix interference capability enable clinical application, which shows compared diagnostic ability with classic methods (100% sensitivity and 100% specificity) but possesses more simplified procedures and shorter turnaround time (<6 h). This colorimetric strategy in a nonsite-specific and hypersensitive manner holds foreseeable prospects in clinical diagnostic and research applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.2c05712DOI Listing

Publication Analysis

Top Keywords

g4/hemin dnazyme
12
visual assay
8
rolling circular
8
circular amplification
8
dnazyme proximity
8
proximity assembly
8
simple operation
8
operation steps
8
detection meca
8
dnazyme
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!