Analytical techniques must be sensitive, specific, and accurate to assess the active pharmaceutical ingredients in pharmaceutical dosage forms. The quality-by-design (QbD) application has proven to be a practical method for magnifying HPLC operations. This article discusses the successfully developed QbD-based stability-indicative LC method for evaluating acetaminophen, caffeine, and aspirin (ASP) in tablet dosage form. To achieve the necessary chromatographic separation, Milli-Q water, methanol, and glacial acetic acid were employed in the following ratios: 63:35:2 (v/v/v) for mobile phase A and 18:80:2 (v/v/v) for mobile phase B. The flow rate, column temperature, and detecting wavelength were 1.0 ml/min, 40°C, and 275 nm, respectively, and an InertSustain C18 analytical column (150 × 4.6 mm, 3 μm) was used. Linearity was between 10.0 and 150.0 μg/ml for ASP and acetaminophen and between 2.6 and 39.0 μg/ml for caffeine. The accuracy findings were more than 97%, and the correlation coefficient for all three components was found to be greater than 0.999. The validated HPLC method yielded reliable and accurate results. ASP was shown to be vulnerable to both acid and alkaline hydrolysis in the forced degradation study. The described method is capable of separating the degradants produced during stress testing and is regarded as stability indicating. The proposed method can be used for a wider range of other formulations with an appropriate diluent selection and sample preparation procedure optimization.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.5585DOI Listing

Publication Analysis

Top Keywords

acetaminophen caffeine
8
caffeine aspirin
8
v/v/v mobile
8
mobile phase
8
method
6
effective stability-indicating
4
stability-indicating method
4
method development
4
development optimization
4
optimization utilizing
4

Similar Publications

Obesity significantly influences drug pharmacokinetics (PK), which challenges optimal dosing. This study examines the effects of diet-and-exercise-induced weight loss on key drug-metabolizing enzymes and gastric emptying in patients with obesity, who frequently require medications for comorbidities. Participants followed a structured weight management program promoting weight loss over 3-6 months and were not concomitantly on potential CYP inducers or inhibitors.

View Article and Find Full Text PDF

3D-printed devices for multiplexed semi-quantitative competitive lateral flow immunoassays.

Anal Methods

January 2025

Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.

Lateral flow immunoassays (LFIAs) are widely used for the simple and rapid detection of various targets at the point of need. However, LFIAs enabling the simultaneous detection of multiple analytes and the possibility for naked-eye semi-quantitative analysis are facing various challenges, including the requirement of large sample volumes, low efficiency, and accuracy. This is particularly the case for the competitive immunoassay format targeting the detection of low molecular weight compounds, such as, for example, drugs.

View Article and Find Full Text PDF

This work presents an optimization of the construction, treatment, and activation of 3D-printed electrochemical sensors (E-3D). For this, was used a 2-full factorial design examining three key variables at two levels: electrode height, electrode diameter, and printing speed. Moreover, it evaluates various physical, chemical, and electrochemical methods to treat and activate the E-3D surface.

View Article and Find Full Text PDF

Babassu (Atallea sp.), a native palm tree from South America's Amazon produces bio-oil and biochar with significant potential for industrial applications. Babassu oil as a bio-based plasticizer is reported here for the first time to replace petrochemical alternatives in the production of conductive filaments for additive manufacturing purposes.

View Article and Find Full Text PDF

Trace organic contaminants (TrOCs), including pharmaceutically active compounds (PhACs), present significant challenges for conventional water treatment processes and pose potential risks to environmental and human health. To address these issues, nanofiltration (NF) and reverse osmosis (RO) membrane technologies have gained attention. This study aims to evaluate the performance of NF and RO membranes in removing TrOCs from wastewater and develop a predictive model using the Solution Diffusion Model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!