A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Four years' results of a prospective, randomized clinical trial comparing polytetrafluoroethylene and modified human umbilical vein for below-knee femoropopliteal bypass. | LitMetric

Polytetrafluoroethylene (PTFE) (Gore-Tex) and human umbilical vein (Biograft) arterial grafts were compared for below-knee femoropopliteal bypass grafting in a prospective randomized clinical trial. One hundred five patients (105 limbs) entered the trial. Seventy-six percent suffered from rest pain, ulceration, or gangrene. The median postoperative ankle-arm blood pressure index was 0.36. Twenty-three limbs had three patent tibial arteries, 46 limbs had two tibial arteries, 31 limbs had one patent artery, and five limbs had isolated popliteal segments. Thirty-four percent were repeat operations. Fifty-five patients were allocated to receive PTFE grafts and 50 to receive human umbilical vein grafts. The two groups were comparable as to preoperative risk factors and operative and postoperative treatment. During the first 4 years (maximum 1609 days) 40 PTFE grafts and 24 umbilical veins occluded. At 1 year the PTFE patency rate was 53% and at 4 years was 22%. For umbilical vein the corresponding figures were 74% and 42% (p = 0.005, Gehan test). During follow-up the incidence of PTFE failure was on the average 2.1 times higher than that of umbilical vein failure (95% confidence limits 1.2 to 3.4).

Download full-text PDF

Source
http://dx.doi.org/10.1067/mva.1987.avs0060506DOI Listing

Publication Analysis

Top Keywords

umbilical vein
20
human umbilical
12
prospective randomized
8
randomized clinical
8
clinical trial
8
below-knee femoropopliteal
8
femoropopliteal bypass
8
tibial arteries
8
arteries limbs
8
ptfe grafts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!