Influence of Kirschner-Wire Insertion Angle on Construct Biomechanics following Tibial Tuberosity Osteotomy Fixation in Dogs.

Vet Comp Orthop Traumatol

Department of Veterinary Administration, Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States.

Published: March 2023

AI Article Synopsis

  • The study examined how the angle of Kirschner wire insertion affects the strength of tibial tuberosity osteotomy fixations in dogs.
  • Two groups were tested: one with wires placed at a transverse angle (0 degrees) and another at a caudodistal angle (30 degrees), finding that the transverse group performed significantly better in terms of yield, peak, and failure forces.
  • The research concluded that inserting Kirschner wires at a transverse angle enhances the stability of the bone repair, making this angle a critical factor in surgical procedures involving tibial tuberosity osteotomy in dogs.

Article Abstract

Objectives:  The aim of this study was to evaluate the effect of Kirschner wire insertion angle on the biomechanical characteristics following tibial tuberosity osteotomy fixation in dogs.

Study Design:  Twelve pairs of cadaveric tibia were harvested and randomly assigned to two treatment groups. Kirschner wires were placed either transversely (0 degrees) or placed caudodistally (30 degrees) with respect to the tibial tuberosity osteotomy. Each limb acted as its own respective control. Radiographic analysis allowed for the calculation of Kirschner wire insertion angle variance. Constructs were tested to monotonic failure while evaluating yield, peak, and failure forces, construct stiffness, and failure mode.

Results:  Kirschner wire insertion angles were 1.1 ± 2.2 degrees and 30.5 ± 2.3 degrees, respectively, for 0-degree and 30-degree groups ( <0.0001). Yield ( = 0.0095), peak ( <0.024) and failure loads ( <0.030) were all significantly greater for Kirschner wires inserted at an angle of 0 degrees compared with 30 degrees. Construct stiffness did not differ regardless of insertion angle ( = 0.068). Failure mode did not differ ( = 0.87) with tibial tuberosity avulsion and Kirschner wire pull-out seen in the majority of constructs (67%).

Conclusion:  Kirschner wires placed transversely (0 degrees) for tibial tuberosity osteotomy fixation were biomechanically superior, increasing yield, peak, and failure forces by 1.6 times, 1.3 times, and 1.4 times, respectively, to those placed in a caudodistal (30 degrees) orientation. Kirschner wire insertion angle is an important consideration following tibial tuberosity osteotomy in dogs, with Kirschner wires placed at 0 degrees conferring increased resistance of the repair to construct deformation.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0042-1759868DOI Listing

Publication Analysis

Top Keywords

insertion angle
12
tibial tuberosity
12
tuberosity osteotomy
12
wire insertion
12
osteotomy fixation
8
kirschner wire
8
influence kirschner-wire
4
insertion
4
kirschner-wire insertion
4
angle construct
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!